English
Language : 

GPC41 Datasheet, PDF (2/2 Pages) SL Power Electronics – 41 WATT GLOBAL PERFORMANCE SWITCHERS
Commercial
Model
Medical
Model
Output
Current
GPC41-5
GPM41-5
5.1 V
6.0 A
GPC41-12
GPM41-12
12 V
3.3 A
GPC41-15
GPM41-15
15 V
2.7 A
GPC41-24
GPM41-24
24 V
1.7 A
GPC41-28
28 V
1.4 A
Note: Add “G” suffix to model number for RoHS compliant model.
GPC41/GPM41 MECHANICAL SPECIFICATIONS
Minimum
Load
0.15
0.03
0.03
0.01
0.01
Load
Regulation
0.75%
0.75%
0.75%
0.75%
0.75%
Initial Setpoint
Tolerance
2%
2%
2%
2%
2%
OVP
Setpoint
6.2 ± 0.6 V
14 ± 1.0 V
19 ± 1.5 V
28± 2.5 V
34 ± 2.8 V
Ripple and
Noise
1%
1%
1%
1%
1%
3
3
ENVIRONMENTAL SPECIFICATIONS
Temperature (A)
Humidity (A)
Shock (B)
Altitude
Vibration (C)
OPERATING
See individual specs.
0 to 95% RH
20 gpk
-500 to 10,000 ft
1.5 g rms’ 0.003 g2/Hz
NON-OPERATING
-40 to +85°C
0 to 95% RH
40 gpk
-500 to 40,000 ft
5 g rms’ 0.026 g2/Hz
A. Units should be allowed to warm up/operate under non-condensing conditions before application of power. Derate output
current and total output power by 2.5% per °C above 50°C. For operation in a confined space, moving air may be required. Under
all conditions, the cooling vs. load profile should be such that heat sinks and/or heatsink temperatures do not exceed 90 °C for
extended periods.
B. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes, total 6 shocks.
C. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating
and 1 hr./axis non-operating.
SL Power Electronics Corp., 6050 King Drive, Bldg.A, Ventura, CA, 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 Email: info@slpower.com. Rev. 4/08.
Data Sheet © 2008 SL Power Electronics Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication.
However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.