GPC200 Datasheet, PDF (2/2 Pages) SL Power Electronics – 200 Watt Global Performance Switchers
GPC200 Commercial/GPM200 Medical 200 Watt Multiple Output
Commercial
Model
GPC200A
Medical
Model
GPM200A
GPC200B GPM200B
GPC200D GPM200D
GPC200E GPM200E
GPC200F GPM200F
Output No.
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
Output
+5 V
+12 V
-12 V
12 V (D)
+5V
+12 V
-5 V
12 V (D)
+5 V
+24 V
-12 V
12 V (D)
+5 V
+24 V
-15 V
15 V (D)
+5 V
+12 V
-12 V
5 V (D)
Output
Minimum
4A
0A
0A
0A
4A
0A
0A
0A
4A
0A
0A
0A
4A
0A
0A
0A
4A
0A
0A
0A
Output
Maximum (B)
18 A
5A
1A
3A
18 A
5A
1A
3A
18 A
3A
1A
3A
18 A
3A
1A
3A
18 A
5A
1A
3A
Output
Maximum (C)
26 A
8A
1.2 A
4A
26 A
8A
1.2 A
4A
26 A
5A
1.2 A
4A
26 A
5A
1.2 A
4A
26 A
8A
1.2 A
4A
Output Peak
32 A
12 A
1.5 A
4.5 A
32 A
12 A
1.5 A
4.5 A
32 A
6.5 A
1.5 A
4.5 A
32 A
6.5 A
1.5 A
4.5 A
32 A
12 A
1.5 A
4.5 A
Noise P-P
50 mV
120 mV
120 mV
120 mV
50 mV
120 mV
50 mV
120 mV
50 mV
240 mV
120 mV
120 mV
50 mV
240 mV
150 mV
150 mV
50 mV
120 mV
120 mV
50 mV
A.Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load.
B. Ratings for unrestricted natural convection cooling; outputs 1 & 2 combined load not to exceed 22A continuous; total power -150W.
C. Ratings with 26cfm forced air cooling; outputs 1 & 2 combined load not to exceed 32A continuous; total power -200W.
D. Isolated output which may be referenced as a positive or negative voltage.
GPC200/GPM200 MECHANICAL SPECIFICATIONS
Total
Regulation (A)
2%
2%
3%
3%
2%
2%
3%
3%
2%
2%
3%
3%
2%
2%
3%
3%
2%
2%
3%
3%
Environmental
Specification
Temperature (A)
Humidity (A)
Shock (B)
Altitude
Vibration (C)
Operating
See individual specs
0 to 95% RH
20 gpk
-500 to 10,000 ft
1.5 grms, 0.003 g2/Hz
Non-operating
-40 to +85oC
0 to 95% RH
40 gpk
-500 to 40,000 ft
5 grms, 0.026 g2/Hz
A. Units should be allowed to warm up/operate under non-condensing conditions
before application of power.
B. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3
orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating.
C. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes,
total 6 shocks.
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033