GPC140 Commercial/GPM140 Medical 140 Watt Multiple Output
Commercial
Model
GPC140-5
Medical
Model
GPM140-5
Output
5V
Output
Minimum
0A
Output
Maximum (B)
26 A
Output
Maximum (C)
30 A
Peak
32 A
Noise P-P
50 mV
Total Regulation (A)
2%
GPC140-12 GPM140-12
12 V
0A
11.7 A
13.4 A
14.6 A
120 mV
2%
GPC140-15 GPM140-15
15 V
0A
9.3 A
10.7 A
11.7 A
150 mV
2%
GPC140-24 GPM140-24
24 V
0A
5.8 A
6.7 A
7.3 A
240 mV
2%
GPC140-28 GPM140-28
28 V
0A
5A
5.7 A
6.3 A
280 mV
2%
A.Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load.
B. Unrestricted natural convection cooling.
C. Requires 26cfm moving air.
GPC140/GPM140 MECHANICAL SPECIFICATIONS
Environmental
Specification
Temperature (A)
Humidity (A)
Shock (B)
Altitude
Vibration (C)
Operating
See individual specs
0 to 95% RH
20 g
pk
-500 to 10,000 ft
1.5 g , 0.003 g2/Hz
rms
Non-operating
-40 to +85oC
0 to 95% RH
40 g
pk
-500 to 40,000 ft
5 g , 0.026 g2/Hz
rms
A. Units should be allowed to warm up/operate under non-condensing conditions
before application of power.
B. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3
orthogonal axes.Tested for 10 min./axis operating and 1 hr./axis non-operating.
C. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes,
total 6 shocks.
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033