English
Language : 

BVL061000003K Datasheet, PDF (2/2 Pages) SL Power Electronics – WIDE RANGE LEAD ACID CHARGERS
BVL
WIDE RANGE LEAD ACID
CHARGERS
Input
Voltage
Line Frequency
Current
Protection
Electrical
Topology
Dielectric Withstand
EMI
CE
MTBF
MTBF
Protection
100-250 VAC -10%, +6%
47 - 63 Hz
0.5 (Lower current with higher voltage)
Internal primary current fuse
Inrush limiting
Environmental
Operating Temperature
Storage Temperature
Relative Humidity
Altitude
Cooling
5º to 40º C with no derating
-30º to +85º C
5% to 95% non-condensing
0-10,000 feet
0-10,000 feet
Convectional - non vented case
Switching - DC battery charger
3000 VAC, 4242 VDC primary- secondary
1500 VAC, 2121 VDC primary-ground
500 DC secondary-ground
Complies with EMC Directives
CE Compliant
100,000 calculated hours
100,000 calculated hours
Foldback overcurrent.
Short circuit protection
Mechanical
Case and Dimensions
Case Material
Weight
Cords and Connectors
LP6 - Desktop
4.20 L x 2.60 W x 1.46 H (in)
107 L x 66 W x 37 H (mm)
Black 94V0 polycarbonate
8 ounces, 210 grams (excluding cord)
6 ft., 2 conductor, 18 AWG, Ault #3
connector. Other connectors are also
available.
Safety Approvals
Agency Listings
CULus 60950; TUV EN60950
Input Configuration
IEC320
w/ground
C14
(F)
Configuration: In Case IEC320 with ground
LED Indicators
Indicator #1 (Green)
Indicator #2 (Amber)
On (unit energized)
Off (unit de-energized)
On (battery discharged)
Off (battery charged)
Connector
Pinout Code
Center contact: positive
Description
Switchcraft 760 plug or equivalent
Suggested Mating
Switchcraft 712A jack or equivalent
Other Connectors are available by special order
AULT INCORPORATED
7105 Northland Terrace | Minneapolis, Minnesota 55428 | USATEL (1) 763-592-1900
FAX (1) 763-592-1911 | E-MAIL info@aultinc.com | WEB www.aultinc.com
© Copyright 2002 Ault Inc.