English
Language : 

TB110S Datasheet, PDF (1/4 Pages) SL Power Electronics – 110W Single Output Test and Measurement/Industrial Series
TB110S
110W Single Output
Test and Measurement/Industrial Series
Features
 2” x 4” x 1.4” Package
 Up to 110W Output Power
 5V @ 1A Standby Output
 Compliant to high levels of EMC per EN61000-4
 15kV ESD (Air), 8kV (Contact)
 4kV Surge
 Meets Class B Conducted EMI with 6db margin,
Class B Radiated EMI with 3db margin
 Up to 90% Efficiency
 >15 years e-cap life
 >1,000,000 hrs. MTBF (50°C)
 Universal Input 90-264Vac Input Range
 DC OK Signal, Inhibit, Power Good Signals
 Class I and II Input Models
 3 Year Warranty
Description
A Superior performance 110 Watts AC to DC power supply designed to ensure easy integration into Test and Measurement and
Industrial applications. Feature rich and highly efficient TB110S product family can easily fit in 1U chassis and provides up to
110Watts. Greater than 15 years operational life as determined by e-cap life calculations, and a 5V@1A standby output are key
features. All models are CE marked to low voltage directive and approved to ITE standards of IEC/UL/EN60950 and CSA C22.2, 2nd
edition.
Model Selection
Model
Number4
Output
Voltage (Nom)
TB110S12K
12V
Output Current
w/Air
Convection
8.7A
6.7A
Efficiency1
89%
Ripple & Noise2
(pk-pk)
120mV
Total
Regulation
±2%
OVP
Threshold
15.0 ± 2.0V
MTBF3
500,000
TB110S24K
24V
4.3A
3.3A
89%
240mV
±2%
28.0 ± 2.5V
500,000
TB110S48K
48V
2.1A
1.6A
89%
480mV
±2%
55.0 ± 4.0V
500,000
Notes:
1.
2.
3.
4.
Efficiency values listed are typical and are measured at 115Vac input, full load output current, at an ambient temperature of 25°C.
Measured at 25°C ambient with noise probe directly at end of 6” twisted pair terminated with 0.1μF ceramic and 10μF low ESR capacitors. Values will be higher at ambient
temperatures below 0°C.
MTBF values are in hours, per Telcordia SR-332, Issue 3, 25°C, full rated load (w/airflow) at 110Vac input.
Change the “K” suffix to “C” for Input Class II (ungrounded) models.
General Specifications
85-264Vac, single phase.
AC Input (Safety Approved to 90-264Vac).
Main Output: <1 Seconds at 115Vac
Turn On Time 5Vsb Output: <250mSec at 115Vac
Input Current 1.8A max. at 110Vac, 0.9A max. at 240Vac
Main Output: <70mSec
Rise Time 5Vsb Output: <70mSec
40Arms max. within 1/2 line cycle, cold start at
Inrush Current 25°C. See application note.
Main Output: 20mSec min.
Hold-up Time 5Vsb Output: 100mSec min.
from loss of AC input at 115 Vac, full load, 25°C.
Earth Leakage
<500mA@264Vac, 60Hz input, NC
Current
Over Load 115% - 200% of rated output current value.
Protection (OCP) Hiccup Mode, Auto-recovery
www.slpower.com
TB110 REV 2.1 27-OCT-16
1