MENB1080_15 Datasheet, PDF (1/2 Pages) SL Power Electronics – Medical Switch-Mode Power Supply
MENB1080
Universal Input 80 Watt Series
Medical Switch-Mode Power Supply
•100-240VAC Universal Input
•Meets EISA2007, CEC Efficiency Level V,
EU (EC) No 278/2009 Phase II
•Desktop Style
•12V to 24V Single Output Models, up to 80W
•Modified and Custom Designs Available
•Regulated Output with Low Ripple
•Impact-Resistant Polycarbonate Enclosure
•No Load Power Consumption <0.5W
•Certified to UL/EN/IEC60601-1, 3rd Edition
3 Year Warranty
RoHS
Specifications
All Specifications are typical at nominal input, full load at 25°C unless otherwise stated.
AC Input
Input Current
100-240Vac, +/-10%, 47-63 Hz, 1∅ MTBF
100Vac: 1.5A Hold-up Time
>100,000 hours calculated
18 ms min. @ 115Vac, 60 ms min. @ 230 Vac
Inrush Current
60A peak @ 264Vac, cold start Overload Protection
Hiccup Mode
Input Fuse
3.15A, 250V Internal Primary Current Fuse provided Short Circuit Protection
Hiccup Mode
Efficiency
Output Voltage
Output Power
Ripple and Noise
Line/Load Regulation
Transient Response
Minimum Load
Meets International Efficiency Level V
See chart
See chart
1% pk-pk max., 20MHz BW
Line: +/- 1 to 2%, Load: +/-5% at end of cable
500μs max., 50% load step, typical
Not required
Topology
Switching – Fixed Frequency Flyback
Safety and EMC Approvals
EN/IEC/CSA/UL60601-1, 3rd Edition
EMC: See chart
Dielectric Withstand
Input-Output: 2 MOOP
Input-GND: 1 MOOP, Output-GND: 500Vdc
Operating Temperature
0° to 40°C, no derating
Storage Temperature
-30 to +85°C
Relative Humidity
5% to 95%, non-condensing
Altitude
0 to 10,000 ft
Case Material
Case Dimensions
Black 94V0 Polycarbonate
131 x 72 x 43mm See outline drawing
Output Connections
Cable: 20AWG, 1,800mm, 4 conductor
Connector: Ault #3, 2.5mm barrel or #51, 6-pin Molex (12V model)
Weight
500g
Conducted Emissions
Radiated Emissions
Voltage Fluctuations
Static Discharge Immunity
Radiated RF Immunity
EFT/Burst Immunity
Line Surge Immunity
Conducted RF Immunity
Power Frequency Magnetic Field Immunity
Voltage Dip Immunity
Line Frequency Harmonics
EMI/EMC Compliance
FCC Part 15, Class B, EN55011 Class B, EN55024
FCC Part 15, Class B, EN55011 Class B, EN55024
EN61000-3-3, Line Flicker
EN61000-4-2, 6kV Contact Discharge, 8kV air discharge
EN61000-4-3, 3V/m.
EN61000-4-4, 2kV/5kHz..
EN61000-4-5, 1kV differential, 2kV common-mode
EN61000-4-6, 3Vrms
EN61000-4-8, 3A/m
EN61000-4-11 crit. A, 100Vac 60Hz, 40%/5 cycles with 70% full load.
EN61000-3-2, Class A
______________________________________________________________________________________________________________________________ 1 of 2
SL Power Electronics Corp • 6050 King Drive Ventura, CA 93003 • Phone 805.486.4565 • Fax 858.712.2040 • Email: info@slpower.com • www.slpower.com