Features
High Efficiency (up to 93%)
Wide Range Universal Input 90-305 VAC
Active Power Factor Correction (0.99 typical)
Constant Current Output
Dimming Function
Lightning Protection
Waterproof (IP67)
Overcurrent, Overvoltage, Overtemperature
Protection
Meets UL8750 & EN61347 Safety
Minimum of 3 Year Warranty, Consult factory
for 5 Years
Description
The LE150S-CD Series operate from a 90 ~ 305Vac input range. These units will provide up to a 1.4 A of
output current and a maximum output voltage of 214Vdc for 150 W maximum output power. They are designed
to be highly efficient and highly reliable. The standard features include dimming control, lightning protection,
over voltage protection, short circuit protection, and over temperature protection.
Model Selection
Model
Output
Number
Current
LE150S140CD 1330mA-1470mA
Output
Voltage
53V – 107V
Efficiency*
110Vac 220Vac
89%-90% 91%-92%
Ripple &
Noise**
3.2V pk-pk max.
Regulation
Line Load
±1% ±3%
Overvoltage
Trip Level
128V – 161V
LE150S70CD
665mA-735mA 107V – 214V 90%-91% 92%-93% 6.5V pk-pk max. ±1%
±3%
257V – 321V
Notes:
1. Efficiency measured at full load, at input voltage noted.
2. Measured at 20MHz bandwidth, with noise probe directly across output terminals, and load terminated with 0.1µF ceramic and 10µF low ESR electrolytic
capacitors.
General Specifications
AC Input 90-305Vac, 47-63Hz, 1∅
Turn On Time 2.0 seconds, max.
Input Current 100Vac: 1.8A, 220Vac: 0.9A
Inrush Current 230Vac, cold start: will not exceed 65A
Input Fuses XA, 250VAC fuses provided on all models
Earth Leakage
Current
<0.75mA@277Vac, 50Hz
Efficiency See Models chart.
Output Power 150W continuous
Dimming 1-10Vdc source or External Resistor can be
Function used for dimming control. See below.
Overload Constant Current
Protection
Short Circuit
Protection
Overvoltage
Protection
Overtemperature
Protection
Provided - no damage to unit, self-recovery.
Latch mode. AC input will need to be reset to
return to normal operation after an OVP
condition. See chart for trip range.
Latch mode. AC input will need to be reset
To return to normal operation after an OTP
condition. Trip Temperature = 110°C typical.
www.slpower.com
LE150S-CD, 15-APRIL-13
1