English
Language : 

GPMP900 Datasheet, PDF (1/3 Pages) SL Power Electronics – High Power Supplies 900 Watt AC/DC Universal Input Power Supply
GPMP900 SERIES SINGLE OUTPUT  MEDICAL POWER SUPPLY
High Power Supplies 900 Watt AC/DC Universal Input Power Supply
• 90 -264 Vac nominal input range
g
• Overvoltage, over temp. and short circuit protection
• Approved to UL, CSA and EN Standards
• Power Good LED
• Low Leakage
• 12 V Auxiliary output
• Medical and commercial approvals
The GPMP Series are universal input AC/DC power supplies with power
factor correction (PFC) with up to 900 Watts ouput power. The GPMP
product incorporates true inhibit, power fail alarm, power good signal and
fan control. The series is approved to EN60601-1 and EN60950-1 to reduce
design-in time and end system compliance costs
SUMMARY
All specifications are typical at nominal input, full load at 25 OC unless otherwise stated
SPECIFICATIONS
OUPUT SPECIFICATIONS
Output Power
Integral forced air
Total Regulation
Rise time
At turn-on
Transient response
Main output 25%
0.2 A/ms
Temperature Coef-
ficient
Overvoltage protection
Short Circuit protection block wall
900 Watts max.
See table
3.0 s max.
3.5% max. dev. 350 ms recovery
to 1%
+/-0.03%/oC
125% +/-10%
Yes
EMC INFORMATION
Conducted emissions EN55011
Radiated emissions EN55011
Line freq. harmonics EN61000-3-2
Voltage fluctuations EN61000-3-3
ESD Air
EN61000-4-2
ESD Contact
EN61000-4-2
Level B
Level A
Class A
Complies (clause 5b)
8 kV contact
6 kV air
Radiated immunity
Fast Transients (EFT)
Line surge immunity
Conducted immunity
Power freq. mag. field
Voltage dip immunity
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
3 V/m
2 kV 5 kHz
1 kV diff /2 kV cm
3 Vrms
3 A/m
Unit will ride through without loss of
output at 75% of rated load with AC
power fail warning.
INPUT SPECIFICATIONS
Input Voltage range
Universal input
Input frequency
Input surge current
Ground Leakage current
Input current
Input current
Input fuse
264 Vac 60 Hz
115 Vac
230 Vac
F1
100-240 nom (90 - 264 max)
Vac
47 Hz to 63 Hz
40 A max.
160 mA
12.0 A max
6.0 A max
15.0 A
ENVIRONMENTAL SPECIFICATIONS
Thermal Performance
operating ambient
(see ratings chart)
non-operating
0 - 50 oC
Fan cooled
Maximum Altitude
operating / non-operating
Relative Humidity
Vibration (operating)
non-condensing
0.003 g2/Hz
Vibration (non-operating) 0.026 g2/Hz
Shock
Shock
half-sine 20 gpk
half-sine 40 gpk
-20 oC to +70 oC
-40 to +85 oC
900 Watts
10,000 ft. / 40,000
ft. max.
5% - 90% RH
1.5 grms 3 axes 10
min/axis
5.0 grms 3 axes, 1
hr/axis
10 ms, 3 axes, 6
shocks total
10 ms, 3 axes, 6
shocks total
Page 1 of 3