English
Language : 

GNT200 Datasheet, PDF (1/3 Pages) SL Power Electronics – Universal Input Power Supply
GNT200
Front End Series 200W AC/DC
Universal Input Power Supply
•Wide Range Input 100-240 VAC with PFC
•Inhibit, Enable, Power Signals and Remote Sense Standard
•Power Density 10-13W/in³
•Compact (3.0” x 5.0” x 1.25”)
•High Efficiency: 90% Typical
•Main Output and Two Auxiliary Outputs
•Conducted EMI meets Class B
•Approved to CSA/EN/IEC/UL 60950-1, 2nd Edition for ITE
•Approved to EN/IEC/UL60601-1 and CSA 22.2 No. 601 for Medical
•Also Available in Class II (G2T200)
•CB Report Available (for IEC60601-1 standard)
2 Year Warranty
Specifications
All Specifications are typical at nominal input, full load at 25°C unless otherwise stated.
AC Input
Input Current
100-240VAC, 50/60 Hz, single phase
80-270VAC, 45-65 Hz max
120VAC: 3A. 230VAC: 1.5A
Turn On Time
Hold-up Time
500 ms max
See chart
Inrush Current
Input Fuses
Limited by internal thermistor. The inrush at 240Vac,
averaged over the first AC half-cycle under cold start
conditions will not exceed 38A.
F1 and F2, 4A/250V
Thermal Considerations
Over/Undershoot
Keeping the following components below
these temps indicates sufficient cooling:
Q1: 90°C max., T4: 110°C max
3.5% max
Power Factor
0.98 typical, 0.96 minimum Overload Protection
Cycling type, 250W nominal limit
Leakage Current
100µA at 120VAC NC, 400µA at 264VAC, SFC Overvoltage Protection
See chart
Output Power
Peak Output Power
200W continuous with 200lfm airflow
See chart for convection ratings
240W for 1 minute, 10% duty cycle
Ripple and Noise
ITE Safety Standards
1% pk-pk max., 20MHz BW,
0.1µF and 10 µF caps on probe
CSA/EN/IEC/UL 60950-1, 2nd Edition
Output Voltage
See chart Medical Safety Standards EN/IEC/UL 60601-1, CSA22.2 No. 601-1
Voltage Adjustability
Minimum Load
Adjustable potentiometer, capable of
±5% change from the nominal setting
Not required
Switching Frequency
MTBF
Output: 195kHz ±12kHz, PFC: 130kHz
300K hours per Telcordia
Total Regulation
See chart Overtemperature Protection
Automatic
Transient Response
500µs to 1%, 50% load step, ∆i/∆t < 0.2A/µs
Maximum voltage deviation is 3.5%
Temperature Coefficient
0.03% per °C typical on all units
Operating Altitude
-500 to 10,000 ft
Non-operating Altitude
-500 to 40,000 ft
Efficiency
90% typical at 230VAC, 87% typical at 120VAC
Operating Temperature
Storage Temperature
Relative Humidity
0 to 70°C (see chart)
-40 to +85°C
5% to 95%, non-condensing
Vibration
5 Hz – 500 Hz, 5 grms Shock
MIL-STD-810E, 516.4 part IV
Model Number Key
GNT 2 XX X G
RoHS Com pliant
Enclosure Options: Blank - no enclosure; F = Fan Cover w ith "U" channel; L = L
bracket, no cover; T = Slotted cover w ith U channel; U = U channel, no cover.
Output Voltage: (See m odels chart below )
Output Pow er (Watts): "2" = 200W
Product Fam ily (GNT = Class I input, G2T = Class II input)
______________________________________________________________________________________________________________________________ 1 of 3
SL Power Electronics Corp • 6050 King Drive Ventura, CA 93003 • Phone 805.486.4565 • Fax 858.712.2040 • Email: info@slpower.com • www.slpower.com