English
Language : 

SKY66299-11 Datasheet, PDF (8/15 Pages) Skyworks Solutions Inc. – 1900 to 2000 MHz High Efficiency 4 W Power Amplifier
DATA SHEET • SKY66299-11: 1900 TO 2000 MHz HIGH EFFICIENCY 4 W POWER AMPLIFIER
Evaluation Board Description
The SKY66299-11 Evaluation Board is used to test the
performance of the SKY66299-11 PA. An Evaluation Board
schematic is provided in Figure 20. Table 6 provides the Bill of
Materials (BOM) list for Evaluation Board components.
An assembly drawing for the Evaluation Board is shown in
Figure 21. Board layer details are shown in Figure 22. Layer detail
physical characteristics are noted in Figure 23.
Circuit Design Considerations
The following design considerations are general in nature and
must be followed regardless of final use or configuration:
 Paths to ground should be made as short as possible.
 The ground pad of the SKY66299-11 has special electrical and
thermal grounding requirements. This pad is the main thermal
conduit for heat dissipation. Because the circuit board acts as
the heat sink, it must shunt as much heat as possible from the
device.
Therefore, design the connection to the ground pad to dissipate
the maximum wattage produced by the circuit board. Multiple
vias to the grounding layer are required.
NOTE: A poor connection between the ground pad and ground
increases junction temperature (TJ), which reduces the life of the
device.
Evaluation Board Test Procedure
Turn-On Sequence
1. Connect 50  Test Equipment or Load to the input and output
RF ports of the Evaluation Board.
2. Connect the DC ground.
3. Connect all VCCs and VBIAS lines to a +5 V supply. Connect
PAEN to a 2.0 V supply.
4. Without applying RF, turn on the 5 V supply, then turn on the 2
V PAEN.
5. Apply RF signal data at –30 dBm and observe that the gain of
the device is approximately 36 dB. Begin measurements.
Turn-Off Sequence
1. Turn off the RF input to the device.
2. Turn off PAEN (set to 0 V).
3. Turn off all VCCs and VBIAS.
NOTE: It is important to adjust the VCC voltage sources so that
+5 V is measured at the board. High collector currents drop the
collector voltage significantly if long leads are used. Adjust the
bias voltage to compensate.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
8
May 31, 2017 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 203291D