DATA SHEET • SKY73033-11 DOWNCONVERSION MIXER
Table 2. SKY73033-11 Absolute Maximum Ratings (Note 1)
Parameter
Symbol
Minimum
Maximum
Units
Supply voltage, +5 V
VCC
4.5
5.5
V
Supply current
ICC
240
mA
RF input power
PRF
+20.0
dBm
LO input power
PLO
+20.0
dBm
Operating case temperature
TC
–40
+85
qC
Junction temperature (Note 2)
TJ
+150
qC
Storage case temperature
TSTG
–40
+125
qC
Note 1: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
Note 2: Nominal thermal resistance (junction to center ground pad) is 5.1 qC/W.
CAUTION: Although this device is designed to be as robust as possible, Electrostatic Discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Table 3. SKY73033-11 Recommended Operating Conditions
Parameter
Symbol
Minimum
Typical
Maximum
Supply voltage, +5 V
VCC
4.75
5.00
5.25
Supply current
ICC
200
LO input power
PLO
–6
0
+6
LO select input:
high
LO_SELH
2.2
low
LO_SELL
0.8
Operating case temperature
TC
–40
+85
RF frequency range
FRF
1700
2200
LO frequency range (Note 1)
FLO
1460
2000
IF frequency range
FIF
40
300
Note 1: The SKY73033-11 has been optimized for low side LO injection. However, the LO can be used outside of the specified frequency range with degraded performance.
Units
V
mA
dBm
V
V
qC
MHz
MHz
MHz
Table 4. SKY73033-11 Electrical Specifications (Note 1) (1 of 2)
(Voltage Supply = +5 V, TC = +25 qC, LO = 0 dBm, RF Frequency = 1748 MHz, IF Frequency = 201 MHz, LO Frequency = 1547 MHz, Unless
Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typical
Max
Units
Conversion gain
G
FRF = 1710 to 1980 MHz,
7.5
8.9
dB
VCC = 4.75 to 5.25 V,
PLO = –3 to +3 dBm
Gain variation over temperature
TC = –40 to +85 °C
r0.8
dB
Noise Figure
NF
9.4
dB
Noise Figure with a blocker signal
NFBLK
Blocking signal input
23
dB
power = +8 dBm
Third order input intercept point
IIP3
FRF = 1748 and 1748.8 MHz,
22.5
24.0
dBm
PRF = –10 dBm/each tone,
VCC = 4.75 to 5.25 V,
PLO = –3 to +3 dBm
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
4