English
Language : 

SKY12329-350LF Datasheet, PDF (4/7 Pages) Skyworks Solutions Inc. – SKY12329-350LF GaAs Digital Attenuator 5-Bit, 1 dB LSB 400 MHz–4 GHz
Data Sheet • SKY12329-350LF
Ins. Loss 4 dB
6 dB
10 dB
12 dB
16 dB
18 dB
22 dB
24 dB
28 dB
0 30 dB
31 dB
3 dB
9 dB
15 dB
21 dB
27 dB
2 dB
8 dB
14 dB
20 dB
26 dB
1 dB
7 dB
13 dB
19 dB
25 dB
5 dB
11 dB
17 dB
23 dB
29 dB
-5
-10
-15
-20
-25
-30
-35
-40
-45
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5
Frequency (GHz)
Input Return Loss vs. Frequency
Truth Table
V1
V2
V3
V4
V5 Attenuation
VHIGH VHIGH VHIGH VHIGH VHIGH Reference insertion loss
VLOW VHIGH VHIGH VHIGH VHIGH
1 dB
VHIGH VLOW
VHIGH VHIGH VHIGH
2 dB
VHIGH VHIGH
VLOW VHIGH VHIGH
4 dB
VHIGH VHIGH VHIGH VLOW VHIGH
8 dB
VHIGH VHIGH VHIGH VHIGH VLOW
16 dB
VLOW VLOW
VLOW VLOW
VLOW
31 dB
2.7 V < VHIGH < 5.5 V, VS = VHIGH ± 0.2 V, 0 < VLOW < 0.2 V.
Part Marking
Lot Number
S329
XXXX
YWW
Part No.
Date Code
Y = Calendar Year
WW = Week
Ins. Loss 1 dB 2 dB
3 dB
4 dB
5 dB
6 dB
7 dB 8 dB
9 dB
10 dB 11 dB
12 dB 13 dB 14 dB 15 dB 16 dB 17 dB
18 dB 19 dB 20 dB 21 dB 22 dB 23 dB
24 dB 25 dB 26 dB 27 dB 28 dB 29 dB
30 dB
0
31 dB
-5
-10
-15
-20
-25
-30
-35
-40
-45
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5
Frequency (GHz)
Output Return Loss vs. Frequency
Absolute Maximum Ratings
Characteristic
Value
RF input power
Control voltage range
Operating temperature range
33 dBm for f > 400 MHz,
VCTL = 0/8 V
-0.2 < VC < 8 V
-40 °C to +85 °C
Storage temperature range
-65 °C to +150 °C
Performance is guaranteed only under the conditions listed in the specifications table and is
not guaranteed under the full range(s) described by the Absolute Maximum specifications.
Exceeding any of the absolute maximum/minimum specifications may result in permanent
damage to the device and will void the warranty.
CAUTION: A lthough this device is designed to be as robust as
possible, ESD (Electrostatic Discharge) can damage
this device. This device must be protected at all
times from ESD. Static charges may easily produce
potentials of several kilovolts on the human body or
equipment, which can discharge without detection.
Industry-standard ESD precautions must be employed
at all times.
Recommended Solder Reflow Profiles
Refer to the “Recommended Solder Reflow Profile”
Application Note.
Tape and Reel Information
Refer to the “Discrete Devices and IC Switch/Attenuators
Tape and Reel Package Orientation” Application Note.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
4
February 20, 2009 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200709 Rev. F