English
Language : 

AAT4674_12 Datasheet, PDF (4/12 Pages) Skyworks Solutions Inc. – Power Supply Selector Switch
DATA SHEET
AAT4674
Power Supply Selector Switch
Electrical Characteristics1
VINX = 5V, TA = -40 to +85°C, unless otherwise noted. Typical values are at TA = 25°C.
Symbol Description
Operation
VIN1
IN1 Operating Voltage Range
VIN2
IN2 Operating Voltage Range
VUVLO_IN1 IN1 Under-Voltage Lockout
VUVLO_IN2 IN2 Under-Voltage Lockout
IIN1_OP IN1 Normal Operating Current2
IIN1_SHDN IN1 Shutdown Mode Current
IIN1_SLP IN1 Sleep Current
IIN2_OP IN2 Normal Operating Current2
IIN2_SHDN IN2 Shutdown Mode Current
IIN2_SLP IN2 Sleep Current
Power Switches
RDS(ON) IN1 IN1-to-OUT FET On-Resistance
RDS(ON) IN2 IN2-to-OUT FET On-Resistance
VDROOP_OUT
OUT Voltage Droop From the Lower Voltage of IN1 and
IN2, When Switching Over Between IN1 and IN2
Current Regulation
tSOFT_START Soft-Start Delay
ILIM_range IN1/IN2 Current Limit Range
ILIM_ACC IN1/IN2 Current Limit Accuracy
Logic Control / Protection
VIH(EN)
VIL(EN)
Logic High Threshold
Logic Low Threshold
TSHDN Chip Thermal Shutdown Temperature
Conditions
Rising edge
Hysteresis
Rising edge
Hysteresis
VIN1 = 5V, VEN = 0V
VIN1 = VEN = 5V, OUT open
VIN1 = 2.5V, VIN2 = 5V, VEN =0V
VIN2 = 5V, VEN = 0V
VIN2 = VEN = 5V, OUT open
VIN1 = 5V, VIN2 = 2.5V, VEN = 0V
VIN1 = 5.0V, TA = 25°C
VIN1 = 3.5V, TA = 25°C
VIN2 = 5.0V, TA = 25°C
VIN2 = 3.5V, TA = 25°C
IO(OUT) = 0.5A, CO(OUT) = 10μF
Delay of start from EN, or UVLO
RIIN1/IIN2 = 100k
Threshold
Hysteresis
Min Typ
2.5
2.5
0.1
0.1
10
1
10
1
0.12
0.14
0.12
0.14
150
100
0.2
0.8 1
1.6
140
15
Max
6
6
2.3
2.3
30
1
5
30
1
5
0.15
0.18
0.15
0.18
2.0
1.2
0.4
Units
V
V
V
V
μA
μA
μA
μA
μA
μA


mV
μs
A
A
V
V
°C
1. The AAT4674 is guaranteed to meet performance specifications over the -40°C to +85°C operating temperature range and is assured by design, characterization, and correla-
tion with statistical process controls.
2. Additional operating current is required by the RIINx current limit setting resistors. The amount of current required by the RIINx resistors is the current limit divided by 1000.
Therefore IINx_OP = (0.5V/RIINx)*(200k/1000) or approximately ILIM/1000.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
4
201911A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • April 26, 2012