Electrical Characteristics1
VCC = 3.0V to 5.5V, TA = -40°C to 85°C unless otherwise noted. Typical values are at TA = 25°C.
Symbol
VCC
IQ
IQU0
IQ(OFF)
ISD(OFF)
VUVLO
RDS(ON)
Description
Operation Voltage
Quiescent Current
Quiescent Current U0
Off Supply Current
Off Switch Current
Under-Voltage Lockout
On-Resistance
ILIMLACC
Lower Current Limit Accuracy
ILIMUACC
ILIM(MIN)
VEN(L)
VEN(H)
IEN(SINK)
TDEL(OFF)
VRDY
VRDYHYS
VRDY(L)
IRDY
OTMP
Upper Current Limit Accuracy
Lower Minimum Current Limit
EN Input Low Voltage
EN Input High Voltage
EN Input Leakage
Turn-Off Delay Time
System READY Trip Threshold
System READY Hysteresis
System READY Voltage Low
RDY Leakage Current
Shutdown Temperature
Conditions
EN IL or EN IU = VCC, IOUT = 0, RHYS = 200k
EN IL = VCC, EN IU = GND, IOUT = 0, ISET = GND,
RHYS = 200k
EN IL = EN IU = VCC
EN IL = EN IU = VCC, VSUPERCAP = 0
Rising edge, 1% hysteresis
VCC =4.75V, RSETL = RSETU = 0k
VCC =3.0V, RSETL = RSETU = 0k
RSETL = 249k; TA ≤ 20°C
RSETL = 249k
RSETU = 1.24M; TA ≤ 20°C
RSETU = 1.24M
VCC =3.0V to 5.5V2
VCC = 3.0V to 5.5V2
VEN = 5.5V
VCC = 5V
VOUT rising, TA = 25°C
RHYS = 200k
ISINK = 1mA
VRDY < 5.5V, VOUT < 98% of VOUT
Min
3.0
Typ
40
Max
5.5
75
Units
V
μA
0.4 1.0
0.4 10
2.7 3.0
50 100
65 120
180 200 220
170 200 230
900 1000 1100
850 1000 1150
75
0.4
1.4
1.0
0.4 1.0
98
200
0.4
1.0
145
μA
μA
V
m
mA
mA
mA
V
V
μA
μs
% of
VOUT
mV
V
μA
°C
1. The AAT4620 is guaranteed to meet performance specification over the -40°C to 85°C operating temperature range and is assured by design, characterization and correlation
with statistical process controls.
2. For VIN outside this range consult the Typical EN Threshold curve.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
4
201943A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • May 15, 2012