English
Language : 

AAT3783_12 Datasheet, PDF (4/20 Pages) Skyworks Solutions Inc. – 1-A Linear Li-Ion/Polymer Battery Charger with 28V Over-Voltage Protection
DATA SHEET
AAT3783
1-A Linear Li-Ion/Polymer Battery Charger with 28V Over-Voltage Protection
Electrical Characteristics1
VIN = 5V, TA = -40°C to +85°C; unless otherwise noted, typical values are at TA = 25°C.
Symbol Description
Operation
VIN_MAX Input Over-Voltage Protection Range
VIN
Normal Operating Input Voltage Range
Over-Voltage Protection
VUVLO
Under-Voltage Lockout Threshold
UVLO Hysteresis
IQ
Operating Quiescent Current
ISD(OFF) Shutdown Supply Current
VOVPT
Over-Voltage Protection Trip Voltage
Battery Charger
VUVLO
Under-Voltage Lockout Threshold
UVLO Hysteresis
VADPP_TH
Adapter Present Indicator Threshold
Voltage, VIN - VBAT
IOP
Operating Current
ISHUTDOWN Shutdown Mode Current
IBAT
Leakage Current from BAT Pin
Voltage Regulation
VBAT_EOC
VCH/VCH
VMIN
Output Charge Voltage Regulation
Output Charge Voltage Tolerance
Preconditioning Voltage Threshold
VRCH
Battery Recharge Voltage Threshold
Current Regulation
ICC_RANGE Charge Current Programmable Range
ICH_CC
Constant-Current Mode Charge Current
VISET
ISET Pin Voltage
KISET
Charge Current Set Factor: ICH_CC/IISET
VTERM
TERM Pin Voltage
ICH_TRK Trickle Charge Current
ICH_TERM Charge Termination Threshold Current
Battery Charging Device
RDS(ON) Total ON Resistance (IN to BAT)
Conditions
Min Typ Max Units
28
V
4.0
7.5
V
Rising Edge
VIN = 5V, ENOVP = 0V, IOUT = 0,
ENCHG = 0V
ENOVP = VIN = 5.5V, VOUT = 0V,
ENCHG = 0V
Rising Edge, OVP = Not Connected
3
V
60
mV
30
50
μA
4
8
μA
6.5
V
Rising Edge
3
VIN > VUVLO
Charge Current = 100mA,
ENOVP = 0V, ENCHG = VIN
VBAT = 4.25V, ENOVP = ENCHG = 0V2
VBAT = 4V, ENOVP = VIN
4
V
150
mV
60
150 mV
0.5
1
mA
0.4
1
μA
0.4
2
μA
4.158 4.20 4.242 V
0.5
%
(Option available for no trickle charge) 2.5
2.6
2.7
V
VBAT_EOC -
0.1
V
VBAT = 3.6V
Constant Current Mode, VBAT = 3.6V
RTERM = 13.3k
TERM Pin Open
RTERM = 13.3 k, ICH_CC  800mA
VIN = 5V, IOUT = 1A
100
-10
5
5
8
2
800
0.2
10
10
10
550
1000 mA
10
%
V
V
15
%
ICH_CC
15
%
ICH_CC
12
%
m
1. The AAT3783 is guaranteed to meet performance specifications over the -40°C to +85°C operating temperature range and is assured by design, characterization and correla-
tion with statistical process controls.
2. Current into charge.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
4
201903B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • April 27, 2012