English
Language : 

AAT3692 Datasheet, PDF (4/19 Pages) Skyworks Solutions Inc. – Dual Input 1.6A Linear Charger with 28V OVP in a 3x4 TDFN Package
DATA SHEET
AAT3692
Dual Input 1.6A Linear Charger with 28V OVP in a 3x4 TDFN Package
Electrical Characteristics1
VADP = VUSB = 5V, TA = -25°C to +85°C, unless otherwise noted. Typical values are at TA = 25°C.
Symbol Description
Operation
VADP_MAX,
VUSB_MAX
VADP, VUSB
Input Over-Voltage Protection Range
ADP and USB Normal Operating Input Voltage
Range
IADP_OP,
IUSB_OP
Operating Current
ISD(OFF) Shutdown Supply Current
ISTANDBY Standby Mode Current
IBAT
Leakage Current from BAT Pin
Over-Voltage Protection
VOVPT
Over-Voltage Protection Trip Voltage
Hysteresis
Battery Charger
VUVLO_ADP, Under-Voltage Lockout Threshold
VUVLO_USB UVLO Hysteresis
Voltage Regulation
VBAT_EOC
VCH/VCH
VMIN
Output Charge Voltage Regulation
Output Charge Voltage Tolerance
Preconditioning Voltage Threshold
VRCH
Battery Recharge Voltage Threshold
Battery Charging Device
RDS(ON) Charging and OVP Total ON Resistance
Current Regulation
ILIM_ADP
ILIM_USB
ICH_CC
VADPSET,
VUSBSET
VTERM
KIADPSET
KIUSBSET
ICH_TRK/
ICH_CC
ICH_TERM/
ICH_CC
ADP Charge Current Programmable Range
USB Charge Current Programmable Range
Constant-Current Mode Charge Current
ADPSET, USBSET Pin Voltage
TERM Pin Voltage
Charge Current Set Factor: ICH_CC/IADPSET
Charge Current Set Factor: ICH_CC/IUSBSET
Trickle Charge Current Percentage
Charge Termination Threshold Current
Percentage
Conditions
Min Typ Max
3.0
VADP or VUSB = 5V, Charge current =
100mA, EN = 0V
VADP or VUSB = 5V, EN = 5V
Charge Terminated
VBAT = 4V, USB and ADP open
Rising edge
7.05
0.5
8
300
1
7.2
300
28
7.05
1.5
4
7.5
Rising edge
3.0
150
4.158
2.4
4.20
0.5
2.6
VBAT_EOC
- 0.1
4.242
2.8
VADP or VUSB = 5V, TA = 25°C
600
VBAT = 3.6V
100
50
-10
RTERM = 13.3kΩ
Constant current mode, VBAT = 3.6V
Constant current mode, VBAT = 3.6V
RADPSET = 8k
5
ICH_CC ≥ 800mA, RTERM = 13.3kΩ
8
1600
500
10
2
0.2
800
800
10
15
10
12
Units
V
V
mA
μA
μA
μA
V
mV
V
mV
V
%
V
V
m
mA
mA
%
V
V
%
%
1. The AAT3692 is guaranteed to meet performance specifications over the -40°C to +85°C operating temperature range and are assured by design, characterization and correla-
tion with statistical process controls.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
4
201895B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • April 27, 2012