English
Language : 

SKY66184-11 Datasheet, PDF (3/14 Pages) Skyworks Solutions Inc. – 2110 to 2170 MHz Linear Power Amplifier
DATA SHEET • SKY66184-11: 2110 TO 2170 MHz LINEAR POWER AMPLIFIER
Technical Description
The SKY66184-11 PA contains all of the needed RF matching and
DC biasing circuits. This three-stage device is optimized for high
linearity and power efficiency. These features make the device
suitable for wideband applications where PA linearity and power
consumption are of critical importance (e.g., small cell and
infrastructure applications).
The device is designed for standard WCDMA and LTE modulated
signals. Under these stringent test conditions, the device exhibits
excellent spectral purity and power efficiency.
Electrical and Mechanical Specifications
The absolute maximum ratings of the SKY66184-11 are provided
in Table 3. The recommended operating conditions are specified
in Table 4, and electrical specifications are provided in Table 5.
Typical performance characteristics are shown in Figures 3
through 6.
Table 3. SKY66184-11 Absolute Maximum Ratings1
Parameter
Symbol
Minimum
Maximum
Units
Supply voltage (VCC)
VCC
0
+4.0
V
Total supply current
ICC
1400
mA
Logic control input voltage (VEN)
Case operating temperature2
VEN
–0.5
3.6
V
TC
–40
+98
C
Storage temperature
TSTG
–55
+150
C
Junction temperature
TJ
+150
C
Thermal resistance
θJC
23
C/W
Power dissipation
PD
4.6
W
Electrostatic discharge:
ESD
Charged Device Model (CDM)
500
V
Human Body Model (HBM)
150
V
1 Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other parameters set
at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
2 Case operating temperature (Tc) refers to the temperature of the bottom ground pad.
CAUTION: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Table 4. SKY66184-11 Recommended Operating Conditions
Parameter
Symbol
Minimum
Frequency range
f
2110
Supply voltage (VCC1, VCC2, VCC3)1
VCC
3.0
PA enable control voltage (active low):
Disable
Enable
VENH
2.5
VENL
0
PA enable current (@ PAEN = 3.6 V)
IEN
Case operating temperature
TC
+25
1 Voltage levels measured at the pads of the package. The Evaluation Board supply voltage levels may be different.
Typical
3.3
+40
Maximum
2170
3.6
3.6
0.6
3.0
+85
Units
MHz
V
V
V
mA
C
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
203259D • Skyworks Proprietary and Confidential Information • Products and Product Information are Subject to Change Without Notice • February 18, 2016
3