English
Language : 

SKY65336-11 Datasheet, PDF (3/12 Pages) Skyworks Solutions Inc. – 2.4 GHz Transmit/Receive Front-End Module with Integrated LNA
DATA SHEET • SKY65336-11 TRANSMIT/RECEIVE FRONT-END MODULE WITH LNA
additional information, refer to Skyworks Application Note, PCB
Design and SMT Assembly/Rework Guidelines for MCM-L
Packages, document number 101752.
Care must be taken when attaching this product, whether it is
done manually or in a production solder reflow environment.
Production quantities of this product are shipped in a standard
tape and reel format. For packaging details, refer to the Skyworks
Application Note, Tape and Reel, document number 101568.
Table 1. SKY65336-11 Signal Descriptions
Pin #
Name
Description
1
BIAS1_PASS
Transmit port bias supply
2
TX_N
Negative transmit input port
3
TX_P
Positive transmit input port
4
GND
Ground
5
GND
Ground
6
BIAS2_PASS
Receive port bias supply
7
RX_N
Negative receive output port
8
RX_P
Positive receive output port
9
GND
Ground
10 GND
Ground
11 RX_VCC
Receive DC supply, +3 V
12 RX_EN
Receive enable
13 GND
Ground
14 GND
Ground
Note: The bottom ground pad must be connected to RF ground.
Pin #
15
16
17
18
19
20
21
22
23
24
25
26
27
28
Name
GND
GND
GND
ANT
GND
GND
GND
GND
GND
TX_VCC
GND
TX_HLB
TX_EN
T_R
Description
Ground
Ground
Ground
Antenna input
Ground
Ground
Ground
Ground
Ground
Transmit DC supply, +3 V
Ground
Transmit power mode
Transmit enable
Transmit/receive switch
Table 2. SKY65336-11 Absolute Maximum Ratings (Note 1)
Parameter
Symbol
Minimum
Maximum
Units
Supply voltage
RX_VCC, TX_VCC
2.1
4
V
Control Voltage
BIAS1_PASS,
BIAS2_PASS, TX_EN,
RX_EN, TX_HLB, T_R
3.6
V
Bypass voltage
BIAS1_PASS, BIAS2_PASS
1.9
V
RF input power, antenna port
PIN_ANT
10
dBm
RF input power, transmit port
PIN_TX
+8
dBm
Case operating temperature
TC
–40
+85
qC
Storage temperature
TST
–55
+125
qC
Junction temperature
TJ
+150
qC
Note 1: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
CAUTION: Although this device is designed to be as robust as possible, Electrostatic Discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
200939G • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 11, 2009
3