ABSOLUTE MAXIMUM RATINGS:
Parameters
DC VDD Voltage Supply
DC Control Pin Voltage
DC VDD Current
Consumption
TX RF Input Power
ANT RF Input Power
Junction Temperature
Storage Ambient
Temperature
Operating Ambient
Temperature
Moisture Sensitivity
ESD HBM
Units
Min
V
0
V
0
mA
dBm
dBm
oC
oC
-40
oC
-40
V +/-4250
RFX8051
Production Data Sheet
Max
3.9
3.6
400
+7
+20
150
+150
+85
Conditions
All VDD Pins
All Control Pins
Through VDD Pins when TX is “ON”
Bypass Mode
Appropriate care required according to
JEDEC Standards
MSL1
All Pins
Note: Sustained operation at or above the Absolute Maximum Ratings for any one or combinations of the above
parameters may result in permanent damage to the device and is not recommended.
All Maximum RF Input Power Ratings assume 50-Ohm terminal impedance.
NOMINAL OPERATING CONDITIONS:
Parameters
Units Min Typ Max
DC VDD Voltage Supply (Note 1)
V
3.0
3.3
3.6
Control Voltage “High” (Note 2)
V
1.2
3.3
Control Voltage “Low”
V
0
0.3
DC Control Pin Current
Consumption
μA
1
DC Shutdown Current
μA
3
PA Turn On/Off Time
μsec
0.5
1
ja (Note 3)
oC/W
42
jc (Note 4)
oC/W
10
LNA Turn On/Off Time
μsec
0.5
1
Shut-Down and “ON” State
Switching Time
μsec
0.5
1
Conditions
All VDD Pins
Note 1: For normal operation of the RFX8051, VDD must be continuously applied to all VDD supply pins.
Note 2: If control voltage can exceed 1.8V, a 1KΩ – 10KΩ series resistor is recommended for the application circuit
on each control line.
Note 3: For operation above +85 ⁰C, use the Θja as guidance for system design to assure the junction temperature
will not exceed the maximum of +150 ⁰C.
Note 4: Case is defined as the bottom of the EVB under the thermal vias.
3