RFX240
Production Data Sheet
ABSOLUTE MAXIMUM RATINGS
Parameters
DC VCC Voltage Supply
DC Control Pin Voltage
DC VCC Current Consumption
TX RF Input Power
ANT RF Input Power
Junction Temperature
Storage Ambient Temperature
Operating Ambient Temperature
ESD Voltage (HBM)
Min
0
0
-50
-40
1000
Max Units
6.0
V
3.6
V
800 mA
+10 dBm
+10 dBm
150
°C
+150 °C
+85
°C
V
Conditions
All VCC Pins
All Control Pins
VCC Pins when PA is Enabled
Appropriate care required according to JEDEC
Standards
All Operating Modes
Human Body Model
Note: Sustained operation at or above the Absolute Maximum Ratings for any single or combinations of the above
parameters may result in permanent damage to the device and is not recommended. All Maximum RF Input Power
Ratings assume 50-Ohm terminal impedance.
GENERAL CHARACTERISTICS
Parameters
Operating Frequency
DC VDD Voltage Supply (Note 1)
Control Voltage “High”
Control Voltage “Low”
Control Pin Current Consumption
DC Shutdown Current
PA Turn On/Off Time
ja (Note 2)
Input Single-Ended Impedance
Min Typ Max Units
Conditions
2.4
2.5 GHz
3.6 5.0 5.5
V
All VDD Pins
1.2
3.6
V
0
0.3
V
1
μA
5
μA
1 µsec
25
oC/W
50
Ω
Note 1 – For normal operation of the RFX240, VDD must be continuously applied to all VDD supply pins.
Note 2 – For operation above +85 ⁰C, use the ja as guidance for system design to assure the junction temperature will
not exceed the maximum of +150 ⁰C.
3
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com