English
Language : 

SKY13306-313LF Datasheet, PDF (2/5 Pages) Skyworks Solutions Inc. – GaAs SPDT Switch 100 MHz–6 GHz
DATA SHEET • SKY13306-313LF
Electrical Specifications
T = 25 °C, VCTL = 0/3 V, ZO = 50 Ω, unless otherwise noted
Parameter
Condition
Insertion loss
J1–J2, J1–J3
Isolation
J1–J2, J1–J3
Return loss
Insertion loss state
Input power for 0.1 dB compression
2nd Harmonic
3rd Harmonic
Input 3rd order intercept point
Control voltage
VHIGH
VLOW
Control port current
PIN = 22 dBm
PIN = 22 dBm
Two tones, 15 dBm each tone, 5 MHz spacing
VCTL = 3 V
VCTL = 5 V
VCTL = 0 V
Frequency
0.10 GHz–6.00 GHz
2.40 GHz–2.50 GHz
3.40 GHz–3.60 GHz
5.15 GHz–5.85 GHz
0.10 GHz–6.00 GHz
2.40 GHz–2.50 GHz
3.40 GHz–3.60 GHz
5.15 GHz–5.85 GHz
0.10 GHz–6.00 GHz
2.40 GHz–2.50 GHz
3.40 GHz–3.60 GHz
5.15 GHz–5.85 GHz
2.4 GHz–2.5 GHz
2.45 GHz
2.45 GHz
5.2 GHz
Min.
Typ.
0.6
0.5
0.5
0.6
21
25
22
25
23
26
21
24
15
25
16
15
35
-70
-68
53
2.7
-0.25
10
15
10
Max.
Unit
0.9
dB
0.7
dB
0.7
dB
0.8
dB
dB
dB
dB
dB
dB
dB
dB
dB
dBm
dBc
dBc
dBm
5
V
0.25
V
100
µA
200
µA
50
µA
Absolute Maximum Ratings
Characteristic
Value
RF input power @ 0,5 V
36.5 dBm @ 25 °C
RF input power @ 0,3 V
36 dBm @ 25 °C
Control voltage
Operating temperature range
-0.2 V < VCTL < 6 V
-40 °C to +85 °C
Storage temperature range
-65 °C to +150 °C
Performance is guaranteed only under the conditions listed in the specifications table and is
not guaranteed under the full range(s) described by the Absolute Maximum specifications.
Exceeding any of the absolute maximum/minimum specifications may result in permanent
damage to the device and will void the warranty.
CAUTION: Although this device is designed to be as robust as
possible, ESD (Electrostatic Discharge) can damage
this device. This device must be protected at all times
from ESD. Static charges may easily produce poten-
tials of several kilovolts on the human body or
equipment, which can discharge without detection.
Industry-standard ESD precautions must be employed
at all times.
Truth Table
V1(1)
V2(1)
J1–J2
J1–J3
0
VHIGH
Isolation
Insertion loss
VHIGH
0
Insertion loss
Isolation
All other conditions not recommended. No damage to the switch will occur if a non-
recommended combination of control voltages is present. The switch will not provide full
isolation or minimum insertion loss under such conditions.
1. 2.7 V < VHIGH < 5 V.
Recommended Solder Reflow Profiles
Refer to the “Recommended Solder Reflow Profile”
Application Note.
Tape and Reel Information
Refer to the “Discrete Devices and IC Switch/Attenuators
Tape and Reel Package Orientation” Application Note.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
2
April 11, 2008 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200745 Rev. C