DATA SHEET • SKY12361-350LF: FOUR-BIT DIGITAL ATTENUATOR
Table 1. SKY12361-350LF Signal Descriptions
Pin
Name
Description
1
VDD
DC power supply
2
RF1
3
N/C
4
RFGND1
5
RFGND2
6
RFGND3
7
N/C
8
RFGND4
RF input/output to digital attenuator
No connection. Can be grounded without
affecting performance.
Connect through external capacitor to
ground. Capacitor value determines lower
frequency operation of attenuator.
Connect through external capacitor to
ground. Capacitor value determines lower
frequency operation of attenuator.
Connect through external capacitor to
ground. Capacitor value determines lower
frequency operation of attenuator.
No connection. Can be grounded without
affecting performance.
Connect through external capacitor to
ground. Capacitor value determines lower
frequency operation of attenuator.
Pin
Name
9
N/C
10 N/C
11 RF2
12 N/C
13 V1
14 V2
15 V3
16 V4
Description
No connection. Can be grounded without
affecting performance.
No connection. Can be grounded without
affecting performance.
RF input/output to digital attenuator
No connection. Can be grounded without
affecting performance.
DC control pin. See Table 4.
DC control pin. See Table 4.
DC control pin. See Table 4.
DC control pin. See Table 4.
Electrical and Mechanical Specifications
The absolute maximum ratings of the SKY12361-350LF are
provided in Table 2. Electrical specifications are provided in
Table 3.
Typical performance characteristics of the SKY12361-350LF are
illustrated in Figures 3 through 8.
The state of the SKY12361-350LF is determined by the logic
provided in Table 4.
Table 2. SKY12361-350LF Absolute Maximum Ratings
Parameter
Symbol
Minimum
Maximum
Units
Supply voltage
VDD
3.3
6.0
V
Control voltage
VCTL
0
VDD
V
RF input power
PIN
+30
dBm
Operating temperature
TOP
–40
+105
C
Storage temperature
TSTG
–40
+125
C
Thermal resistance
RTH
50 (IL state)
C/W
Electrostatic discharge:
ESD
Charged Device Model (CDM), Class C3
Human Body Model (HBM), Class 1B
Machine Model (MM), Class A
1000
V
500
V
100
V
Note: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
CAUTION: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
2
May 30, 2014 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202874A