English
Language : 

HY19-12 Datasheet, PDF (2/4 Pages) Alpha Industries – 90 Degree Hybrid 1.85-1.99 GHz
DATA SHEET • HY19-12, HY19-12LF
Pin Out
RF In
GND
GND
ISOL.
Direct
GND
GND
Coupled
Typical Performance Data
ZO = 50 Ω, unless otherwise noted
-3.0
-3.2
Direct
-3.4
-3.6
Coupled
-3.8
-4.0
1.85 1.87 1.89 1.91 1.93 1.95 1.97 1.99
Frequency (GHz)
Path Losses vs. Frequency
1.00
0.75
0.50
0.25
0
-0.25
-0.50
-0.75
-1.00
1.85 1.87 1.89 1.91 1.93 1.95 1.97 1.99
Frequency (GHz)
Amplitude Balance vs. Frequency
The Pin Out diagram shows the HY19-12 configured for a
divider/coupler with Pin 1 as the input port and a 50 Ω
termination to be placed at Pin 3. Since the HY19-12 is
symmetric, any nonground pin may be used as the input
port. The following table shows the possible pin connection
combinations for the HY19-12 used as a divider/coupler:
Input
Pin 1
Pin 4
Pin 5
Pin 8
Termination
Pin 4
Pin 1
Pin 8
Pin 5
Direct
Pin 8
Pin 5
Pin 4
Pin 1
Coupled
Pin 5
Pin 8
Pin 1
Pin 4
1.30
1.25
1.20
1.15
1.10
1.05
1.00
1.85 1.87 1.89 1.91 1.93 1.95 1.97 1.99
Frequency (GHz)
Input VSWR vs. Frequency
1.30
1.25
1.20 Coupled
1.15
1.10 Direct
1.05
1.00
1.85 1.87 1.89 1.91 1.93 1.95 1.97 1.99
Frequency (GHz)
Output VSWR vs. Frequency
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
2
June 8, 2006 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200234 Rev. B