AAT1138 Datasheet, PDF (15/21 Pages) Skyworks Solutions Inc. – 2A Step-Down Converter with Adjustable Input Current Limit
DATA SHEET
AAT1138
2A Step-Down Converter with Adjustable Input Current Limit
To 2A step-down converter, the maximum dropout volt-
age is:
VDropout_Buck = 2A · 200mΩ = 0.4V
Operation in Heavy Load Pulse
When a heavy load pulse is applied to the output of
AAT1138 as typical application shows, the input current
is limited to the value of ILIM determined by RSET. At this
time, CSYSOUT has the important role of providing enough
current and voltage to the step-down converter input to
bring it into regulation. The duty cycle of the heavy load
pulse should not exceed the maximum value which allows
sufficient time to charge CSYSOUT from VIN and balance the
capacitor charging and discharging to make the operation
normally. Figure 2 shows the operation waveform at 5V
VIN and 3.8V VOUT with a 2A load pulse applied when RSET
= 11.5kΩ, CIN = 1μF, CSYSOUT = 22μF ceramic capacitor +
4x330μF tantalum capacitor, and COUTB = 22μF.
VIN
(100mV/div)
5V
VSYSOUT
(AC Coupled)
(1V/div)
VOUT
3.8V
(200mV/div)
IIN
(500mA/div)
0A
IOUT
0A
(2A/div)
Time (1ms/div)
Figure 2: AAT1138 Operation Waveform when 2A
217Hz 12.5% Load Pulse is Applied.
Capacitor Selection
CSYSOUT Selection
CSYSOUT is not only the load switch output capacitor but
also the step-down converter input capacitor. It is
designed to provide the additional input current and
maintain the SYSOUT voltage for the step-down con-
verter when load switch limits the input current from
SYSIN. If the input voltage of the step-down converter
(VPVIN and VSVIN) is lower than the VOUT plus the dropout
voltage, the AAT1138 enters dropout mode.
CSYSOUT minimum value can be calculated by the following
steps:
First, calculate the allowed maximum delta voltage on
CSYSOUT to keep Vout in regulation:
∆VSYSOUT = VIN - VOUT - VDropout_Switch - VDropout_Buck
Second, calculate the required input current at SYSOUT
for the step-down converter:
IBUCKIN =
VOUT · IOUT
(VIN - V ) Dropout_Switch · η
Next, calculate the maximum current CSYSOUT should pro-
vide:
ICSYSOUT = IBUCKIN - ILIM
Finally, derive the CSYSOUT at certain load on period TON.
CSYSOUT_Min =
ICSYSOUT · TON
ΔVSYSOUT
Example: A 2A 217Hz 12.5% load pulse is applied on
3.8V VOUT in 5V VIN and 500mA load switch current limit.
Under the condition, VDropout_Switch is 0.15V. VDropout_Buck is
0.4V. Therefore:
∆VSYSOUT = 5 - 3.8 - 0.15 - 0.4 = 0.65V