English
Language : 

SP6660 Datasheet, PDF (7/22 Pages) Sipex Corporation – 200mA Charge Pump Inverter or Doubler
TYPICAL PERFORMANCE CHARACTERISTICS
VIN = +3.6V, TAMB = 25oC unless otherwise noted. LF = Low Frequency, FC = Open, C1 = C2 = 150µF.
HF = High Frequency, FC = V+, C1 = C2 = 22µF. Inverter Circuit use Figure 1. Doubler Circuit use Figure 2.
g
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0.0
0
50
100
150
Load Current (mA)
Figure 5. Output Voltage Drop vs. Load Current – Inverter LF
V+ = 3.6V
V+ = 2.5V
V+ = 1.5V
200
250
100
95
V+ = 3.6V
V+ = 2.5V
90
V+ = 1.5V
85
80
75
70
65
60
0
50
100
150
200
250
Load Current (mA)
Figure 6. Power Efficiency vs. Load Current – Inverter LF
-4
-3
-2
-1
0
1
2
3
4
5
6
7
8
1
Inverter IL = 10mA
Inverter IL = 100mA
Inverter IL = 200mA
Doubler IL = 10mA
Doubler IL = 100mA
Doubler IL = 200mA
10
100
Oscillator Frequency (kHz)
Figure 7. Output Voltage vs. Oscillator Frequency
SP6660DS/11
SP6660 200mA Charge Pump Inverter or Doubler
7
1000
© Copyright 2000 Sipex Corporation