ELECTRICAL CHARACTERISTICS
Unless otherwise noted VCC = +3.3 ±0.3V, ambient temperature TMIN < TA < TMAX. Typical values are at VCC = 3.3,
ambient temperature TA = +25ºC. The ♦ denotes the specifications which apply over the full operating range
unless otherwise noted.
PARAMETERS
SYM MIN TYP MAX UNITS ♦
CONDITIONS
Input Current (A and B)
Half Duplex
Thermal-Shutdown Threshold
Thermal Shutdown Hysteresis
RECEIVER
Receiver Differential Threshold
(Sensitivity)
Receiver Input Hysteresis
RO Output High Voltage
RO Output Low Voltage
Tri-State Output Current at
Receiver
Receiver Input Resistance
Receiver Output Short-Circuit
Current
SUPPLY CURRENT
IA,B
-100
125
µA
♦ DE = GND
VIN = +12V
VCC = GND or 3.6 VIN = -7V
TTS
165
ºC ♦
TTSH
15
ºC ♦
VTH -200 -125 -50
mV
-7V≤ VCM ≤ 12V
∆ VTH
15
VOH
Vcc -
0.6
VOL
0.4
mV ♦ Va + Vb = 0V
V
♦ IO = -1mA
V
♦ IO = 1mA
IOZR
+/-1
µA
♦ 0≤ VO ≤ VCC
RIN
96
kΩ
♦ -7V ≤ VCM ≤ 12V
IOZR
±60 mA
0V ≤ VRO ≤ VCC
Supply Current
Supply Current in Shutdown
mode
ESD PROTECTION
ICC
ISHDN
0.8 1.5
0.8 1.5
0.8 1.5
0.05 3
No Load, RE = 0, DE = VCC
mA ♦ No Load, RE = VCC, DE = VCC
No Load, RE = 0, DE = 0
µA
RE = VCC, DE = GND
±15
ESD Protection for Y, Z, A, and B
±15
±8
Human Body Model
kV ♦ Air Gap (IEC 1000-4-2)
Contact (IEC 1000-4-2)
Date: 03/31/05
SP3070E - SP3078E Family, ± 15kV ESD-Protected, Failsafe RS-485/RS422 Transceivers
4