SP619 Datasheet, PDF (2/7 Pages) Sipex Corporation – High Current Power Switch | |||
|
◁ |
Absolute Maximum Ratings
Vinâ¦â¦â¦.â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦.â¦.â¦-0.3V to 7V
These are stress ratings only and functional op- Storage Temperature..â¦....â¦â¦â¦.⦠-65°C to 150°C
eration of the device at these ratings or any other Junction Temperature..................... â¦â¦..â¦â¦.150°C
above those indicated in the operation sections of Lead Temperature (Soldering, 10 sec)......â¦â¦.300°C
the specifications below is not implied. Exposure to ESD RATING
absolute maximum rating conditions for extended
periods of time may affect reliability.
Human Body Modelâ¦â¦â¦â¦â¦â¦â¦â¦â¦.â¦â¦.2000V
Machine Modelâ¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦....200V
OPERATING RATINGS
Thermal resistance SOT23-6
Junction to Ambientâ¦â¦â¦â¦â¦â¦â¦â¦â¦.â¦.â¦.191°C
Junction to lead â¦â¦â¦â¦â¦â¦â¦â¦...â¦â¦â¦â¦â¦50°C
RECOMMENDED OPERATING CONDITIONS
Unless otherwise specified: Vin = 2.5V - 7V, Cin = 0.1µF, Ta = -40°C to + 85°C
PARAMETER
CONDITIONS
MIN TYP (Note 1)
MAX
UNITS
Operating Input Voltage
Range
2.5
7
V
Overcurrent Deactivation
Range
EN=1.5V
725
800
1010
mA
Overcurrent Duration Be-
EN=1.5V
1
fore Deactivation
5.25
ms
Shutdown Supply Current
Vin=4.2V
2
µA
Quiescent Supply Current
EN=1.5V Vin=4.2V
Iout=0mA
350
µA
Quiescent Supply Current
EN=1.5V Vin=4.2V
Iout=725mA
5.25
mA
Rds(on)
Vin=2.5V Iout=100mA
EN=1.5V
.377
â¦
Post Fault Output Load for
Recovery
Enable=1.5V
10
15
23
Kâ¦
Post Fault Activation Turn
Enable=1.5V
1
On Time
55
ms
Thermal Shutdown Die
SP619 will self recover
120
150
Temperature
when temperature drops
below the trip point .
180
°C
Thermal Restart Die Tem-
perature
90
120
135
°C
ENABLE Logic LOW
Driver is disabled
.5
V
ENABLE Pin Logic HIGH
Driver is active
.655
1.4
V
Turn On Delay
Rl=100kâ¦, Cl= 0.01µF
(Note 2,3)
600
µs
Turn Off Delay
Rl=100kâ¦, Cl= 0.01µF
(Note 2,4)
200
µs
Rise Time
Rl=100kâ¦, Cl= 0.01µF
(Note 2)
100
µs
Fall Time
Rl=100kâ¦, Cl= 0.01µF
(Note 2)
2500
µs
Note 1: Typicals are Tj=25°C
Note 2: Characterized, not 100% tested
Note 3: Turn on delay is measured from the time the enable pin is turned on to the time it takes the output to rise to 10% of its
final value.
Note 4: Turn off delay is measured from the time the enable pin is turned to the time it takes for the output to fall to 90% of its
current value.
Jul23-07 Rev K
SP619 High Current Power Switch
© 2007 Sipex Corporation
|
▷ |