English
Language : 

SA1412 Datasheet, PDF (4/5 Pages) Silan Microelectronics Joint-stock – TWO CELL LI+ BATTERY PROTECTION CIRCUIT
SA1412
external mosfet off and on. There are four opration modes as follows:
1. Overcharge mode:
The battery voltage of either the H or L cell goes above overcharge detection voltage. The IC shuts down the
charging loop.Detection operation delay for overcharge detection can be set with the dead time setting pin.
2. Normal mode
The battery voltage of both H and L cells is above overdischarge detection voltage and below overcharge
detection voltage.
3. Overdischarge mode
The battery voltage of either the H or L cell drops below overdischarge detection voltage. The IC shuts down
the discharging loop.Dead time for overdischarge detection is set internally.
4. Overcurrent mode
The voltage between CS-GND goes above overcurrent detection voltage during discharge. The IC shuts down
the discharging loop.
TEST CIRCUIT
HANGZHOU SILAN MICROELECTRONICS CO.,LTD
Http: www.silan.com.cn
REV:2.2 2007.09.28
Page 4 of 5