EZR32WG230F256 Datasheet, PDF (74/87 Pages) Silicon Laboratories – EZR32WG Wireless MCUs EZR32WG230 Data Sheet
EZR32WG230 Data Sheet
Pinout and Package
5.3 Alternate Functionality Pinout
A wide selection of alternate functionality is available for multiplexing to various pins. This is shown in the table. The table shows the
name of the alternate functionality in the first column, followed by columns showing the possible LOCATION bitfield settings.
Note: Some functionality, such as analog interfaces, do no have alternate settings or a LOCATION bitfield. In these cases, the pinout is
shown in the column corresponding to the LOCATION 0.
Table 5.2. Alternate functionality overview
Alternate
LOCATION
Functionality
0
1
2
3
4
ACMP0_CH6
PC6
ACMP0_CH7
PC7
ACMP0_O
PE2 PD6
ACMP1_CH4
PC12
ACMP1_CH5
PC13
ACMP1_CH6
PC14
ACMP1_CH7
PC15
ACMP1_O
PF2 PE3 PD7
ADC0_CH0
PD0
ADC0_CH1
PD1
ADC0_CH2
PD2
ADC0_CH3
PD3
ADC0_CH4
PD4
ADC0_CH5
PD5
ADC0_CH6
PD6
ADC0_CH7
BOOT_RX
BOOT_TX
BU_STAT
BU_VIN
BU_VOUT
CMU_CLK0
CMU_CLK1
DAC0_N1 /
OPAMP_N1
PD7
PD6
PD7
PE3
PD8
PE2
PC12 PD7
PA1 PD8
PD7
5
Description
Analog comparator ACMP0, channel 6.
Analog comparator ACMP0, channel 7.
Analog comparator ACMP0, digital output.
Analog comparator ACMP1, channel 4.
Analog comparator ACMP1, channel 5.
Analog comparator ACMP1, channel 6.
Analog comparator ACMP1, channel 7.
Analog comparator ACMP1, digital output.
Analog to digital converter ADC0, input channel number
0.
Analog to digital converter ADC0, input channel number
1.
Analog to digital converter ADC0, input channel number
2.
Analog to digital converter ADC0, input channel number
3.
Analog to digital converter ADC0, input channel number
4.
Analog to digital converter ADC0, input channel number
5.
Analog to digital converter ADC0, input channel number
6.
Analog to digital converter ADC0, input channel number
7.
Bootloader RX.
Bootloader TX.
Backup Power Domain status, whether or not the sys-
tem is in backup mode
Battery input for Backup Power Domain
Power output for Backup Power Domain
Clock Management Unit, clock output number 0.
Clock Management Unit, clock output number 1.
Operational Amplifier 1 external negative input.
silabs.com | Smart. Connected. Energy-friendly.
Rev. 1.1 | 73