|
SI7020-A20 Datasheet, PDF (5/36 Pages) Silicon Laboratories – IC HUMIDITY AND TEMPERATURE SENSOR | |||
|
◁ |
Si7020-A20
Table 2. General Specifications (Continued)
1.9 < VDD < 3.6 V; TA = â40 to 85 °C (G grade) or â40 to 125 °C (I/Y grade); default conversion time unless otherwise noted.
Parameter
Symbol
Test Condition
Min
Conversion Time1
tCONV
12-bit RH
â
11-bit RH
â
10-bit RH
â
8-bit RH
â
14-bit temperature
â
13-bit temperature
â
12-bit temperature
â
11-bit temperature
â
Powerup Time
tPU
From VDD ⥠1.9 V to ready for a
â
conversion, 25 °C
From VDD ⥠1.9 V to ready for a
â
conversion, full temperature range
After issuing a software reset
â
command
Typ
Max Unit
10
12
5.8
7
3.7
4.5
2.6
3.1
ms
7
10.8
4
6.2
2.4
3.8
1.5
2.4
18
25
â
80
ms
5
15
Notes:
1. Initiating a RH measurement will also automatically initiate a temperature measurement. The total conversion time will
2.
be
No
tcCoOnNvVe(rRsHio)n+otrCIO2CNVt(rTan).saction
in
progress.
Typical
values
measured
at
25
°C.
3. Occurs once during powerup. Duration is <5 msec.
4. Occurs during I2C commands for Reset, Read/Write User Registers, Read EID, and Read Firmware Version. Duration is
<100 µs when I2C clock speed is >100 kHz (>200 kHz for 2-byte commands).
5. Additional current consumption when HTRE bit enabled. See Section â5.5. Heaterâ for more information.
Rev. 1.1
5
|
▷ |