AN610
Command 0x12. SET_PROPERTY
Sets a property shown in Table 10, “AM/SW Receiver Command Summary,” on page 34. The CTS bit is set when it
is safe to send the next command. This command may only be sent when in power up mode.
Command Arguments: Five
Response bytes: None
Command
Bit
CMD
ARG1
ARG2
ARG3
ARG4
ARG5
ARG Bit
1 7:0
2 7:0
3 7:0
4 7:0
5 7:0
D7
D6
D5
D4
D3
D2
D1
D0
0
0
0
1
0
0
1
0
0
0
0
0
0
0
0
0
PROPH[7:0]
PROPL[7:0]
PROPDH[7:0]
PROPDL[7:0]
Name
Reserved
PROPH
PROPL
PROPDH
PROPDL
Always write to 0.
Function
Property High Byte.
This byte in combination with PROPL is used to specify the property to modify
Property Low Byte.
This byte in combination with PROPH is used to specify the property to modify
Property Value High Byte.
This byte in combination with PROPDL is used to specify the property to modify
Property Value Low Byte.
This byte in combination with PROPDH is used to specify the property to modify
46