Si4012
5.1.1. COMMAND: GET_REV
Purpose: Return product and revision information for the device.
ARG:
None
DATA:
Product ID, Revision ID.
Command:
GET_REV
7
6
5
4
3
2
1
0
Command
CMD
0x10
Response:
GET_REV 7
6
5
4
3
2
1
0
Reply
STATUS CTS
Err
DATA1
ProdId[31:24]
DATA2
ProdId[23:16]
DATA3
ProdId[15:8]
DATA4
ProdId[7:0]
DATA5
RevisionID_RMIDU[47:40]
DATA6
RevisionID_RMIDU[39:32]
DATA7
RevisionID_RMIDL[31:24]
DATA8
RevisionID_RVID[23:16]
DATA9
RevisionID_FWIDU[15:8]
DATA10
RevisionID_FWIDL[7:0]
18
Rev 1.0