EZR32WG-868MHZ Datasheet, PDF (13/29 Pages) Silicon Laboratories – Packet Trace Interface support
6. Advanced Energy Monitor
EZR32WG 868MHz Wireless Starter Kit
Advanced Energy Monitor
6.1 Introduction
Any embedded developer seeking to make his embedded code spend as little energy as the underlying architecture supports, needs
tools to easily and quickly discover inefficiencies in the running application.
This is what the Simplicity Energy Profiler is designed to do. It will in real-time graph and log current as a function of time while correlat-
ing this to the actual target application code running on the EZR32. There are multiple features in the profiler software that allows for
easy analysis, such as markers and statistics on selected regions of the current graph or aggregate energy usage by different parts of
the application.
6.2 Advanced Energy Monitor - Theory of operation
The AEM circuitry on the board is capable of measuring current signals in the range of 0.1uA to 150mA, which is close to 123dBs of
dynamic range. It can do this while stil maintaining approximately 10kHz of current signal bandwidth. This is accomplished through a
combination of a highly capable current sense amplifier, multiple gain stages and signal processing within the kit's board controller be-
fore the current sense signal is read by a host computer for display and/or storage.
The current sense amplifier measures the voltage drop over a small series resistor, and the gain stage further amplifies this voltage with
two different gain settings to obtain two current ranges. The transition between these two ranges occurs around 250 µA.
The current signal is combined with the target MCU's Program Counter (PC) sampling by utilizing a feature of the ARM CoreSight de-
bug architecture. The ITM (Instrumentation Trace Macrocell) block can be programmed to sample the MCU's PC at periodic intervals
( 50kHz ) and output these over SWO pin ARM devices. When these two data streams are fused and correlated with the running appli-
cation's memory map, an accurate statistical profile can be built over time, that shows the energy profile of the running application in
real-time.
At kit power-up or on a power-cycle, and automatic AEM calibration is performed. This calibration compensates for any offset errors in
the current sense amplifiers.
Figure 6.1. Advanced Energy Monitor
silabs.com | Smart. Connected. Energy-friendly.
Rev. 1.21 | 10