Electrical Specifications VIN = VDD= 12V, fSW = 533kHz, TA = -40°C to +85°C, unless otherwise noted. Typical values are at
TA = +25°C. Boldface limits apply across the operating temperature range, -40°C to +85°C. (Continued)
SYMBOL
PARAMETER
TEST CONDITIONS
MIN
MAX
(Note 12) TYP (Note 12) UNIT
OSCILLATOR AND SWITCHING CHARACTERISTICS
fSW_RANGE
fSW_ACCY
Switching Frequency Range
Switching Frequency Set-point
Accuracy
296
1067
kHz
-5
+5
%
EXT_SYNCPW
Minimum Pulse Width Required from
External SYNC Clock
Measured at 50% Amplitude
150
ns
EXT_SYNCDRIFT Drift Tolerance for External SYNC Clock External SYNC Clock equal to 500kHz
-10
is not supported
+10
%
LOGIC INPUT/OUTPUT CHARACTERISTICS
ILOGIC_BIAS
Bias Current at the Logic Input Pins
VLOGIC_IN_LOW Logic Input Low Threshold Voltage
VLOGIC_IN_HIGH Logic Input High Threshold Voltage
VLOGIC_OUT_LOW Logic Output Low Threshold Voltage
VLOGIC_OUT_HIGH Logic Output High Threshold Voltage
PMBus INTERFACE TIMING CHARACTERISTIC
DDC, EN, MGN, PG, SA, SCL, SDA,
SALRT, SYNC, UVLO, VMON, VSET
2mA sinking
2mA sourcing
-100
2.0
2.25
+100
nA
0.8
V
V
0.5
V
V
fSMB
PMBus Operating Frequency
100
400
kHz
NOTES:
12. Compliance to datasheet limits is assured by one or more methods: Production test, characterization and/or design. Controller is independently
tested before module assembly.
13. VOUT measured at the termination of the VSENP and VSENN sense points.
14. The MAX load current is determined by the thermal “Derating Curves” on page 15,
15. “FS” stands for full scale of recommended maximum operation range.
16. “tSW” stands for time period of operation switching frequency.