 AC Electrical Characteristics
Table 8 Measurement Conditions
Input pulse voltage
Input pulse rise / fall time
Output determination voltage
Output load
VIH = 0.9 × VDD, VIL = 0.1 × VDD
20 ns
VOH = 0.5 × VDD, VOL = 0.5 × VDD
100 pF + pull-up resistor 1 kΩ
SDA
VDD
R = 1 kΩ
C = 100 pF
Remark The power supplies of the IC
and load have the same
electrical potential.
Figure 7 Output Load Circuit
Table 9 AC Electrical Characteristics
(Ta = −40°C to +105°C)
Item
Symbol
VDD*2 ≥ 1.3 V
Min. Typ. Max.
VDD*2 ≥ 3.0 V
Min. Typ. Max.
Unit
SCL clock frequency
fSCL
0
−
100
0
−
400 kHz
SCL clock low time
tLOW
4.7
−
−
1.3
−
−
μs
SCL clock high time
SDA output delay time*1
tHIGH
tPD
4
−
−
0.6
−
−
μs
−
−
3.5
−
−
0.9 μs
Start condition setup time
tSU.STA
4.7
−
−
0.6
−
−
μs
Start condition hold time
tHD.STA
4
−
−
0.6
−
−
μs
Data input setup time
tSU.DAT
250
−
−
100
−
−
ns
Data input hold time
tHD.DAT
0
−
−
0
−
−
μs
Stop condition setup time
tSU.STO
4.7
−
−
0.6
−
−
μs
SCL, SDA rise time
tR
−
−
1
−
−
0.3 μs
SCL, SDA fall time
tF
−
−
0.3
−
−
0.3 μs
Bus release time
tBUF
4.7
−
−
1.3
−
−
μs
Noise suppression time
tI
−
−
100
−
−
50
ns
*1. Since the output format of the SDA pin is Nch open-drain output, SDA output delay time is determined by the values of
the load resistance (RL) and load capacity (CL) outside the IC. Therefore, use this value only as a reference value.
*2. Regarding the power supply voltage, refer to " Recommended Operation Conditions".
tF
tHIGH
tLOW
tR
SCL
tSU.STA tHD.STA
SDA
(S-35390A H Series input)
tHD.DAT tSU.DAT
SDA
(S-35390A H Series output)
8
tPD
Figure 8 Bus Timing
Seiko Instruments Inc.
tSU.STO
tBUF