English
Language : 

S-8239BAA-M6T1U Datasheet, PDF (7/25 Pages) Seiko Instruments Inc – OVERCURRENT MONITORING IC
Rev.1.1_03
OVERCURRENT MONITORING IC FOR MULTI-SERIAL-CELL PACK
S-8239B Series
2. Ta = −40°C to +85°C*1
Table 6
(Ta = −40°C to +85°C*1 unless otherwise specified)
Item
Symbol
Condition
Min.
Typ.
Max.
Unit
Test
Condition
Test
Circuit
Detection Voltage
Overcurrent 1 detection voltage VDIOV1
−
VDIOV1
− 0.021
VDIOV1
VDIOV1
+ 0.021
V
1
1
Overcurrent 2 detection voltage*2 VDIOV2
−
VDIOV2
− 0.130
VDIOV2
VDIOV2
+ 0.130
V
1
1
Overcurrent 3 detection voltage
VDIOV3
Overcurrent 3 detection function
"available"
0.70
1.20
1.70
V
1
1
UVLO detection voltage
Release Voltage
VUVLO
−
1.85 2.00 2.15 V
1
1
Overcurrent release voltage
VRIOV
Input Voltage, Operation Voltage
VDD criteria, VDD = 3.5 V
0.5 1.2 1.7 V
1
1
Operation voltage between
VDD pin and VSS pin
VDSOP Output logic is determined*3
1.5
−
8
V
−
−
Current Consumption
Current consumption during
normal operation
Current consumption during
power-down
IOPE
VDD = 3.5 V, VVM = 0 V
IPDN
VDD = VVM = 1.5 V
0.7 3.5 8.0 μA
2
2
−
− 0.15 μA
2
2
Internal Resistance
Internal resistance between
VM pin and VDD pin
RVMD VDD =1.8 V, VVM = 0 V
78 300 1310 kΩ
3
3
Output Resistance
DO pin resistance "L"
Delay Time
RDOL VDD = VVINI = 3.5 V, VDO = 0.5 V 1.2
5
15 kΩ
4
4
Overcurrent 1 detection delay
time
tDlOV1
−
tDIOV1
× 0.2
tDIOV1
tDIOV1
× 1.8
ms
5
5
Overcurrent 2 detection delay
time
tDlOV2
−
tDIOV2
× 0.2
tDIOV2
tDIOV2
× 1.8
ms
5
5
Overcurrent 3 detection delay
time
tDlOV3
Overcurrent 3 detection function
"available"
56
280 504
μs
5
5
UVLO detection delay time
tUVLO
−
0.98 4.90 8.82 s
5
5
*1. Since products are not screened at high and low temperatures, the specification for this temperature range is
guaranteed by design, not tested in production.
*2. Even if overcurrent 1 detection voltage and overcurrent 2 detection voltage are in the same range, VDIOV1 is lower than
VDIOV2.
*3. It indicates that DO pin output logic is determined.
7