English
Language : 

S-814 Datasheet, PDF (7/32 Pages) Seiko Instruments Inc – LOW DROPOUT CMOS VOLTAGE REGULATOR
Rev.2.1_00
LOW DROPOUT CMOS VOLTAGE REGULATOR
S-814 Series
„ Electrical Characteristics
Table 5
(Ta=25°C unless otherwise specified)
Item
Symbol
Conditions
Min.
Typ.
Max.
Units
Test
circuit
Output voltage*1
VOUT(E)
VIN=VOUT(S)+1 V, IOUT=30 mA
VOUT(S) VOUT(S) VOUT(S)
×0.98
×1.02
V
1
Output current*2
IOUT
2.0 V≤VOUT(S)≤2.9 V 100*3 ⎯
⎯ mA
3
VOUT(S)+1 V≤VIN≤10 V
3.0 V≤VOUT(S)≤3.9 V
4.0 V≤VOUT(S)≤4.9 V
110*3
135*3
⎯
⎯
⎯ mA
⎯ mA
3
3
5.0 V≤VOUT(S)≤6.0 V 180*3 ⎯
⎯ mA
3
2.0 V≤VOUT(S)≤2.4 V
⎯ 0.51 0.87 V
1
2.5 V≤VOUT(S)≤2.9 V
⎯ 0.38 0.61 V
1
3.0 V≤VOUT(S)≤3.4 V
⎯ 0.30 0.44 V
1
Dropout voltage*4 Vdrop
IOUT=60 mA
3.5 V≤VOUT(S)≤3.9 V
⎯ 0.24 0.33 V
1
4.0 V≤VOUT(S)≤4.4 V
⎯ 0.20 0.26 V
1
4.5 V≤VOUT(S)≤4.9 V
⎯ 0.18 0.22 V
1
5.0 V≤VOUT(S)≤5.4 V
⎯ 0.17 0.21 V
1
5.5 V≤VOUT(S)≤6.0 V
⎯ 0.17 0.20 V
1
Line regulation 1
ΔVOUT1
ΔVIN • VOUT
VOUT(S)+0.5 V≤VIN≤10 V, IOUT=30 mA
⎯ 0.05 0.2 %/V 1
Line regulation 2
ΔVOUT2
ΔVIN • VOUT
VOUT(S)+0.5 V≤VIN≤10 V, IOUT=10 μA
⎯ 0.05 0.2 %/V 1
Load regulation
Output voltage
temperature
cofficient*5
ΔVOUT3
VIN=VOUT(S)+1 V, 10 μA≤IOUT≤80 mA
ΔVOUT VIN=VOUT(S)+1 V, IOUT=30 mA,
ΔTa • VOUT −40°C≤Ta≤85°C
⎯ 30 50 mV 1
⎯
±100
⎯
ppm/
°C
1
Current
consumption during ISS1
operation
VIN=VOUT(S)+1 V, ON/OFF pin=ON, No load
⎯ 30 40 μA
2
Current
consumption during ISS2
shutdown
Input voltage
VIN
ON/OFF pin input
voltage “H”
VSH
ON/OFF pin input
voltage “L”
VSL
VIN=VOUT(S)+1 V, ON/OFF pin=OFF, No load ⎯ 0.1 0.5 μA
2
⎯
VIN=VOUT(S)+1 V, RL=1 kΩ,
Judged at VOUT level
VIN=VOUT(S)+1 V, RL=1 kΩ,
Judged at VOUT level
⎯
⎯
10
V
1
1.5 ⎯ ⎯
V
4
⎯ ⎯ 0.3 V
4
ON/OFF pin input
current “H”
ISH
VIN=VOUT(S)+1 V, VON/OFF=7 V
−0.1 ⎯ 0.1 μA
4
ON/OFF pin input
current “L”
ISL
VIN=VOUT(S)+1 V, VON/OFF=0 V
−0.1 ⎯ 0.1 μA
4
Short current limit IOS
VIN=VOUT(S)+1 V, VOUT pin=0 V
⎯ 70 ⎯ mA 3
Ripple rejection RR
VIN=VOUT(S)+1 V, f=100 Hz, ΔVrip=0.5 Vrms,
IOUT=30 mA
⎯
45
⎯
dB
5
*1. VOUT(E): Effective output voltage
i.e., The output voltage when fixing IOUT(=30 mA) and inputting VOUT(S)+1.0 V.
VOUT(S): Specified output voltage
*2. Output amperage when output voltage goes below 95 % of VOUT(E) after gradually increasing output current.
*3. The output current can be at least this value.
Use load amperage not exceeding this value.
Seiko Instruments Inc.
7