English
Language : 

S-5852ABCAC-A8T1U4 Datasheet, PDF (7/15 Pages) Seiko Instruments Inc – HIGH-ACCURACY DIGITAL TEMPERATURE SENSOR
HIGH-ACCURACY DIGITAL TEMPERATURE SENSOR WITH THERMOSTAT FUNCTION
Rev.1.2_00
S-5852A Series
 AC Electrical Characteristics
Table 9 Measurement Conditions
Input pulse voltage
Input pulse rising / falling time
Output reference voltage
Output load
0.2 × VDD to 0.8 × VDD
20 ns or less
0.3 × VDD to 0.7 × VDD
100 pF + 1 kΩ pull-up
reisitance
Input pulse voltage
0.8 × VDD
Output reference voltage
0.7 × VDD
0.2 × VDD
0.3 × VDD
Figure 3 Input / Output Waveform during AC Measurement
Item
SCL clock frequency
SCL clock time "L"
SCL clock time "H"
SDA output delay time
SDA output hold time
SCL, SDA rising time
SCL, SDA falling time
Data input setup time
Data input hold time
Start condition setup time
Start condition hold time
Stop condition setup time
Bus release time
Noise suppression time
Symbol
fSCL
tLOW
tHIGH
tAA
tDH
tR
tF
tSU.DAT
tHD.DAT
tSU.STA
tHD.STA
tSU.STO
tBUF
tI
Table 10
VDD = 1.7 V to 3.6 V
Min.
Max.
0
400
1.3
−
0.6
−
0.1
0.9
50
−
0.02
0.3
0.02
0.3
100
−
0
−
0.6
−
0.6
−
0.6
−
1.3
−
−
50
VDD = 2.2 V to 3.6 V
Unit
Min.
Max.
0
1000
kHz
0.5
−
μs
0.26
−
μs
0.1
0.45
μs
50
−
ns
−
0.12
μs
−
0.12
μs
50
−
ns
0
−
ns
0.26
−
μs
0.26
−
μs
0.26
−
μs
0.5
−
μs
−
50
ns
SCL
tF
tSU.STA
tHD.STA
tHIGH
tLOW
tHD.DAT
tSU.DAT
SDA
(Input)
SDA
(Output)
tAA
tDH
Figure 4 Bus Timing
tR
tSU.STO
tBUF
7