English
Language : 

S-5732NSL1I-Y3N2U Datasheet, PDF (7/21 Pages) Seiko Instruments Inc – HIGH-WITHSTAND VOLTAGE HIGH-SPEED
HIGH-WITHSTAND VOLTAGE HIGH-SPEED UNIPOLAR DETECTION TYPE HALL IC
Rev.2.1_00
S-5732 I Series
 Magnetic Characteristics
1. Product with S pole detection
1. 1 Product with BOP = 3.0 mT typ.
Item
Operation point*1
Release point*2
Hysteresis width*3
S pole
S pole
S pole
Symbol
BOPS
BRPS
BHYSS
Table 8
(Ta = +25°C, VDD = 12.0 V, VSS = 0 V unless otherwise specified)
Condition
Min.
Typ.
Max. Unit Test Circuit
−
1.2
3.0
4.8
mT
4
−
0.8
2.0
3.6
mT
4
BHYSS = BOPS − BRPS
−
1.0
−
mT
4
1. 2 Product with BOP = 6.0 mT typ.
Table 9
(Ta = +25°C, VDD = 12.0 V, VSS = 0 V unless otherwise specified)
Item
Symbol
Condition
Min.
Typ.
Max. Unit Test Circuit
Operation point*1 S pole
BOPS
−
3.0
6.0
9.0
mT
4
Release point*2
S pole
BRPS
−
2.5
4.5
7.5
mT
4
Hysteresis width*3 S pole
BHYSS
BHYSS = BOPS − BRPS
−
1.5
−
mT
4
*1. BOPN, BOPS: Operation points
BOPN and BOPS are the values of magnetic flux density when the output voltage (VOUT) changes after the magnetic flux
density applied to this IC by the magnet (N pole or S pole) is increased (by moving the magnet closer).
Even when the magnetic flux density exceeds BOPN or BOPS, VOUT retains the status.
*2. BRPN, BRPS: Release points
BRPN and BRPS are the values of magnetic flux density when the output voltage (VOUT) changes after the magnetic flux
density applied to this IC by the magnet (N pole or S pole) is decreased (the magnet is moved further away).
Even when the magnetic flux density falls below BRPN or BRPS, VOUT retains the status.
*3. BHYSN, BHYSS: Hysteresis widths
BHYSN and BHYSS are the difference between BOPN and BRPN, and BOPS and BRPS, respectively.
Remark The unit of magnetic density mT can be converted by using the formula 1 mT = 10 Gauss.
7