English
Language : 

S-75V00ANC Datasheet, PDF (64/68 Pages) Seiko Instruments Inc – MINI LOGIC SERIES 2 INPUT NAND GATE
MINI LOGIC SERIES EXCLUSIVE OR GATE
S-75L86ANC
Rev.2.2_00
„ AC Characteristics
CL=15 pf, Input tr=tf=6 ns, VCC=3.3±0.3 V, Ta=25°C (unless otherwise specified)
Parameter
Symbol
Measurement Conditions
MIN. TYP. MAX. Unit
Output Rise/Fall Time tTLH, tTHL

Propagation Delay Time tPLH, tPHL


4.0
8.0
ns

6.0
9.0
Parameter
Symbol
CL=25 pf, Input tr=tf=6 ns (unless otherwise specified)
Measurement Conditions
Ta=25°C
Ta=-40 to 85°C Unit
VCC(V) Min. Typ. Max. Min. Max.
Output Rise/Fall Time
tTLH,
tTHL
1.0

35
70

90
1.5

15
25

30
3.0

7
10

14
ns
Propagation Delay Time
tPLH,
tPHL
1.0

30
60

75
1.5

15
25

30
3.0

7
10

14
Input Capacitance
CIN


5
10

10
pF
Equiv. Int. Capacitance CPD*1


10



pF
*1. CPD is the no-load equivalent capacitance inside the circuitry. Refer to the measurement circuit shown
below.
Current consumption is averaged by the following equation.
ICC(opr)=CPD y VCC y fin+ICC
Measurement Circuit
6 ns
6 ns
VIN
PG
50 Ω
VOUT
VIN
tPLH
CL
50%
VOUT
90%
50%
10%
tPHL
50%
Remark No-load output during measurement of current consumption.
VCC
GND
VOH
VOL
„ Input Pin Equivalent Circuit
Input pin
64
Seiko Instruments Inc.