English
Language : 

S24C16C-H Datasheet, PDF (6/35 Pages) Seiko Instruments Inc – FOR AUTOMOTIVE OPERATION 2-WIRE SERIAL E2PROM
FOR AUTOMOTIVE 105°C OPERATION 2-WIRE SERIAL E2PROM
S-24C16C H Series
Rev.2.2_01_H
 AC Electrical Characteristics
Table 11 Measurement Conditions
Input pulse voltage
0.2 × VCC to 0.8 × VCC
Input pulse rising / falling time 20 ns or less
Output reference voltage
Output load
0.3 × VCC to 0.7 × VCC
100 pF
Input pulse voltage
0.8 × VCC
Output reference voltage
0.7 × VCC
0.3 × VCC
0.2 × VCC
Figure 4 Input / Output Waveform during AC Measurement
Item
SCL clock frequency
SCL clock time "L"
SCL clock time "H"
SDA output delay time
SDA output hold time
Start condition setup time
Start condition hold time
Data input setup time
Data input hold time
Stop condition setup time
SCL, SDA rising time
SCL, SDA falling time
WP setup time
WP hold time
WP release setup time
WP release hold time
Bus release time
Noise suppression time
Table 12
Ta = −40°C to +105°C
Symbol
VCC = 2.5 V to 5.5 V
Unit
Min.
Max.
fSCL
tLOW
tHIGH
tAA
tDH
tSU.STA
tHD.STA
tSU.DAT
tHD.DAT
tSU.STO
tR
tF
tWS1
tWH1
tWS2
tWH2
tBUF
tI
0
400
kHz
1.3
−
μs
0.6
−
μs
0.1
0.9
μs
50
−
ns
0.6
−
μs
0.6
−
μs
100
−
ns
0
−
ns
0.6
−
μs
−
0.3
μs
−
0.3
μs
0
−
μs
0
−
μs
0
−
μs
0
−
μs
1.3
−
μs
−
50
ns
SCL
tF
tSU.STA
tHD.STA
tHIGH
tLOW
tHD.DAT
tSU.DAT
SDA
(input)
SDA
(output)
6
tAA
tDH
Figure 5 Bus Timing
tR
tSU.STO
tBUF