English
Language : 

S-93A86A Datasheet, PDF (6/29 Pages) Seiko Instruments Inc – CMOS SERIAL E2PROM
CMOS SERIAL E2PROM
S-93A86A
Rev.2.1_00
„ AC Electrical Characteristics
Table 10 Test Conditions
Input pulse voltage
Output reference voltage
Output load
0.1 × VCC to 0.9 × VCC
0.5 × VCC
100 pF
Table 11
Item
Symbol
VCC = 4.5 to 5.5 V
VCC = 2.7 to 4.5 V
Unit
Min. Typ. Max. Min. Typ. Max.
CS setup time
tCSS
0.2
—
—
0.4
—
—
µs
CS hold time
tCSH
0
—
—
0
—
—
µs
CS deselect time
tCDS
0.2
—
—
0.2
—
—
µs
Data setup time
tDS
0.1
—
—
0.2
—
—
µs
Data hold time
tDH
0.1
—
—
0.2
—
—
µs
Output delay time
Clock frequency*1
tPD
—
—
0.4
—
—
1.2
µs
fSK
0
—
2.0
0
—
0.5 MHz
Clock pulse width
tSKH, tSKL
0.1
—
—
0.5
—
—
µs
Output disable time
tHZ1, tHZ2
0
—
0.2
0
—
0.5
µs
Output enable time
tSV
0
—
0.15
0
—
0.5
µs
*1. The clock cycle of the SK clock (frequency: fSK) is 1/fSK µs. This clock cycle is determined by a combination
of several AC characteristics, so be aware that even if the SK clock cycle time is minimized, the clock cycle
(1/fSK) cannot be made to equal tSKL(Min.) + tSKH(Min.).
Item
Write time
Table 12
Symbol
tPR
VCC = 2.7 to 5.5 V
Unit
Min.
Typ.
Max.

2.0
5.0
ms
6