S-57A1NSL1A-M3T2U Datasheet, PDF (6/15 Pages) Seiko Instruments Inc – HIGH-SPEED UNIPOLAR DETECTION TYPE HALL IC
FOR AUTOMOTIVE 125°C OPERATION HIGH-WITHSTAND VOLTAGE HIGH-SPEED UNIPOLAR DETECTION TYPE HALL IC
S-57A1 A Series
Rev.1.6_01
 Magnetic Characteristics
1. Product with S pole detection
1. 1 Product with BOP = 3.0 mT typ.
Item
Operation point*1
Release point*2
Hysteresis width*3
S pole
S pole
S pole
Symbol
BOPS
BRPS
BHYSS
Table 6
(Ta = +25°C, VDD = 12.0 V, VSS = 0 V unless otherwise specified)
Condition
Min.
Typ.
Max. Unit Test Circuit
−
1.5
3.0
4.5
mT
4
−
1.0
2.0
3.3
mT
4
BHYSS = BOPS − BRPS
−
1.0
−
mT
4
1. 2 Product with BOP = 6.0 mT typ.
Item
Operation point*1
Release point*2
Hysteresis width*3
S pole
S pole
S pole
Symbol
BOPS
BRPS
BHYSS
Table 7
(Ta = +25°C, VDD = 12.0 V, VSS = 0 V unless otherwise specified)
Condition
Min.
Typ.
Max. Unit Test Circuit
−
3.0
6.0
9.0
mT
4
−
2.5
4.5
7.5
mT
4
BHYSS = BOPS − BRPS
−
1.5
−
mT
4
2. Product with N pole detection
2. 1 Product with BOP = 6.0 mT typ.
Item
Operation point*1
Release point*2
Hysteresis width*3
N pole
N pole
N pole
Symbol
BOPN
BRPN
BHYSN
Table 8
(Ta = +25°C, VDD = 12.0 V, VSS = 0 V unless otherwise specified)
Condition
Min.
Typ.
Max. Unit Test Circuit
−
−9.0
−6.0
−3.0
mT
4
−
−7.5
−4.5
−2.5
mT
4
BHYSN = |BOPN − BRPN|
−
1.5
−
mT
4
*1. BOPN, BOPS: Operation points
BOPN and BOPS are the values of magnetic flux density when the output voltage (VOUT) changes after the magnetic flux
density applied to the S-57A1 A Series by the magnet (N pole or S pole) is increased (by moving the magnet closer).
Even when the magnetic flux density exceeds BOPN or BOPS, VOUT retains the status.
*2. BRPN, BRPS: Release points
BRPN and BRPS are the values of magnetic flux density when the output voltage (VOUT) changes after the magnetic flux
density applied to the S-57A1 A Series by the magnet (N pole or S pole) is decreased (the magnet is moved further
away).
Even when the magnetic flux density falls below BRPN or BRPS, VOUT retains the status.
*3. BHYSN, BHYSS: Hysteresis widths
BHYSN and BHYSS are the difference between BOPN and BRPN, and BOPS and BRPS, respectively.
Remark The unit of magnetic density mT can be converted by using the formula 1 mT = 10 Gauss.
6