English
Language : 

S8200A Datasheet, PDF (5/36 Pages) Seiko Instruments Inc – BATTERY PROTECTION IC FOR 1-CELL PACK
Rev.4.0_00
BATTERY PROTECTION IC FOR 1-CELL PACK
S-8200A Series
Table 4
Delay Time
Combination
Overcharge
Detection
Delay Time
[tCU]
Overdischarge
Detection
Delay Time
[tDL]
Discharge Overcurrent
Detection
Delay Time
[tDIOV]
Load Short-circuiting
Detection
Delay Time
[tSHORT]
Charge Overcurrent
Detection
Delay Time
[tCIOV]
(1)
1.0 s
64 ms
8 ms
250 μs
8 ms
(2)
1.0 s
32 ms
8 ms
250 μs
8 ms
(3)
256 ms
32 ms
8 ms
250 μs
16 ms
(4)
1.0 s
128 ms
8 ms
250 μs
8 ms
(5)
1.0 s
128 ms
16 ms
500 μs
16 ms
(6)
1.0 s
128 ms
16 ms
250 μs
8 ms
Remark The delay times can be changed within the range listed in Table 5. For details, please contact our sales office.
Delay Time
Symbol
Overcharge detection delay time
tCU
Overdischarge detection delay time
tDL
Discharge overcurrent detection delay time tDIOV
Load short-circuiting detection delay Time tSHORT
Charge overcurrent detection delay time
tCIOV
*1. This value is the delay time of the standard product.
Table 5
Selection Range
256 ms 512 ms 1.0 s*1
32 ms 64 ms*1 128 ms
4 ms
8 ms*1
16 ms
250 μs*1 500 μs
1 ms
4 ms
8 ms*1
16 ms
Remark
Select a value from the left.
Select a value from the left.
Select a value from the left.
Select a value from the left.
Select a value from the left.
Seiko Instruments Inc.
5