English
Language : 

S-8209BAA-T8T1Y Datasheet, PDF (5/26 Pages) Seiko Instruments Inc – BATTERY PROTECTION IC
Rev.3.6_00
BATTERY PROTECTION IC WITH CELL-BALANCE FUNCTION
S-8209B Series
3. Please contact our sales office for the products with detection voltage value other than those specified
above.
Users are able to select the overcharge detection voltage, overcharge release voltage, cell-balance
detection voltage and cell-balance release voltage from the range shown in Figure 2 and Figure 3.
Users are able to select how to combine the overcharge detection voltage (VCU) and the overcharge release
voltage (VCL) from the range A or B shown in Figure 2*1.
Similarly, select how to combine the cell-balance detection voltage (VBU) and the cell-balance release
voltage (VBL) from the range of C or D in Figure 3*2.
In selecting the combination of VCU and VCL from the range A, select the combination of VBU and VBL from
the range C. Similarly, in selecting the combination of VCU and VCL from the B range, select the combination
of VBU and VBL from the range D*3.
4.40
4.40
4.20
A
4.20
C
3.90
B
3.90
D
3.55
3.55
3.50 3.55
3.80 3.90 4.00
4.40
Overcharge release voltage (VCL) [V]
3.50 3.55
3.80 3.90 4.00
4.40
Cell-balance release voltage (VBL) [V]
Figure 2
Figure 3
*1. Users are able to select the overcharge hysteresis voltage (VCU − VCL) in 0 V to 0.4 V, in 50 mV step.
*2. Users are able to select the cell-balancce hysteresis voltage (VBU − VBL) in 0 V to 0.4 V, in 50 mV step.
*3. Select as to set VCU > VBU.
5