S-80830C Datasheet, PDF (34/54 Pages) Seiko Instruments Inc – ULTRA-SMALL PACKAGE HIGH-PRECISION VOLTAGE DETECTOR
ULTRA-SMALL PACKAGE HIGH-PRECISION VOLTAGE DETECTOR
S-808xxC Series
Rev.3.2_00
3. Change of Detection Voltage
In Nch open-drain output products of the S-808xxC series, detection voltage can be changed using
resistance dividers or diodes as shown in Figures 30 to 31. In Figure 30, hysteresis width also changes.
VDD
VDD
RA*1
(RA≤75 kΩ) VIN
S-
808xxCN
OUT
Vf1
Vf2
VIN
S-
808xxCN
OUT
+
RB
−
(Nch open-drain
output products)
VSS
Detection voltagae = RA + RB • −VDET
RB
Hysterisis width = RA + RB • VHYS
RB
*1. RA should be 75 kΩ or less to prevent oscillation.
(Nch open-drain
output product)
VSS
Detection voltage=Vf1+Vf2+(−VDET)
Caution If RA and RB are large, the hysteresis
width may aloso be larger than the value
given by the above equation due to the
through-type current (which flows
slightly in an Nch open-drain product).
Figure 30
Figure 31
Caution The above connection diagram and constants do not guarantee correct operation. Perform
sufficient evaluation using the actual application to set the constants.