English
Language : 

S24C08C Datasheet, PDF (26/35 Pages) Seiko Instruments Inc – FOR AUTOMOTIVE 105C OPERATION
FOR AUTOMOTIVE 105°C OPERATION 2-WIRE SERIAL E2PROM
S-24C08C H Series
Rev.2.2_00_H
6. Data hold time (tHD.DAT = 0 ns)
If SCL and SDA of the S-24C08C are changed at the same time, it is necessary to prevent a start / stop condition from
being mistakenly recognized due to the effect of noise.
The S-24C08C may error if it does not recognize a start / stop condition correctly during transmission.
It is recommended to set the delay time of 0.3 μs minimum from a falling edge of SCL for the SDA.
This is to prevent the S-24C08C from going in a start / stop condition due to the time lag caused by the load of the bus
line.
tHD.DAT = 0.3 μs min.
SCL
SDA
Figure 28 S-24C08C Data Hold Time
7. SDA pin and SCL pin noise suppression time
The S-24C08C includes a built-in low-pass filter at the SDA pin and the SCL pin to suppress noise. This means that if
the power supply voltage is 5.0 V, noise with a pulse width of 130 ns or less can be suppressed.
For details of the assurable value, refer to noise suppression time (tl) in Table 12.
300
Noise Suppression Time (tI) max.
200
[ns]
100
2
3
4
5
Power supply voltage (VCC)
[V]
Figure 29 Noise Suppression Time for the SDA Pin and the SCL Pin
26
Seiko Instruments Inc.