S-35399A03 Datasheet, PDF (25/51 Pages) Seiko Instruments Inc – 2-WIRE REAL-TIME CLOCK | |||
|
◁ |
Rev.1.0_00
2-WIRE REAL-TIME CLOCK
S-35399A03
3. Per-minute edge interrupt output
Per-minute edge interrupt output is the function to output âLâ from the INT1 / INT2 pin, when the first minute-carry
processing is done, after selecting the output mode. To set the pin output to âHâ, turn off the output mode of per-minute
edge interrupt. In the INT1 pin output mode, input â0â in INT1ME in the status register 2. In the INT2 pin output mode,
input â0â in INT2ME.
Status register 2 setting
⢠INT1 pin output mode
32kE = 0, INT1AE = Donât care (0 or 1), INT1FE = 0
⢠INT2 pin output mode
INT2AE = Donât care (0 or 1), INT2FE = 0
Change by program
INT1ME/INT2ME
INT1 pin/INT2 pin
Minute-carry processing OFF
Minute-carry
processing
"L" is output again if this period is within 7.9 ms*1.
*1. Pin output is set to âHâ by disabling the output mode within 7.9 ms, because the signal of this procedure is
maintained for 7.9 ms. Note that pin output is set to âLâ by setting enable the output mode again.
Figure 27 Timing of Per-Minute Edge Interrupt Output
4. Minute-periodical interrupt output 1
The minute-periodical interrupt 1 is the function to output the one-minute clock pulse (Duty 50%) from the INT1 / INT2
pin, when the first minute-carry processing is done, after selecting the output mode.
Status register 2 setting
⢠INT1 pin output mode
32kE = 0, INT1AE = 0
⢠INT2 pin output mode
INT2AE = 0
Change by program (OFF)
INT1ME, INT1FE
INT2ME, INT2FE
Minute-carry
processing
Minute-carry
processing
Minute-carry
processing
Minute-carry
processing
Minute-carry
processing
INT1 pin/INT2 pin
30 s 30 s 30 s 30 s 30 s 30 s 30 s 30 s 30 s
"L" is output again if this period is within 7.9 ms*1.
"H" is output again if this period is within 7.9 ms.
"L" is output at the next minute-carry processing
*1. Setting the output mode disable makes the pin output âHâ, while the output from the INT1 / INT2 pin is in âLâ.
Note that pin output is set to âLâ by setting enable the output mode again.
Figure 28 Timing of Minute-periodical Interrupt Output 1
Seiko Instruments Inc.
25
|
▷ |