S25A080A Datasheet, PDF (21/33 Pages) Seiko Instruments Inc – FOR AUTOMOTIVE 125°C OPERATION
Rev.4.2_00
FOR AUTOMOTIVE 125°C OPERATION SPI SERIAL E2PROM
S-25A080A/160A/320A, S-25A080B/160B/320B
Status Register
BP1
BP0
0
0
0
1
1
0
1
1
Table 25 Block Settings of Write Protect
Area of Write Protect
Address of Write Protect Block
S-25A080A,
S-25A160A,
S-25A320A,
S-25A080B
S-25A160B
S-25A320B
0%
25%
50%
100%
None
300h to 3FFh
200h to 3FFh
000h to 3FFh
None
600h to 7FFh
400h to 7FFh
000h to 7FFh
None
C00h to FFFh
800h to FFFh
000h to FFFh
Mode
WP Pin
1
Software Protect
1
(SPM)
X
X
Hardware Protect
0
(HPM)
0
Remark X = Don't care
Table 26 Protect Operation
Bit SRWD Bit WEL Write Protect Block
X
0
Write disable
X
1
Write disable
0
0
Write disable
0
1
Write disable
1
0
Write disable
1
1
Write disable
General Block
Write disable
Write enable
Write disable
Write enable
Write disable
Write enable
Status Register
Write disable
Write enable
Write disable
Write enable
Write disable
Write disable
 Hold Operation
The hold operation is used to pause serial communications without setting this IC in the non-select status. In the hold
status, the serial data output goes in "High-Z", and both of the serial data input and the serial clock go in "Don't care".
Be sure to set the chip select ( CS ) to "L" to set this IC in the select status during the hold status.
Generally, during the hold status, this IC holds the select status. But if setting this IC in the non-select status, the
users can finish the operation even in progress. Figure 19 shows the hold operation.
These are two statuses when the serial clock (SCK) is set to "L".
• If setting hold ( HOLD ) to "L", hold ( HOLD ) is switched at the same time the hold status starts.
• If setting hold ( HOLD ) to "H", hold ( HOLD ) is switched at the same time the hold status ends.
These are two statuses when the serial clock (SCK) is set to "H".
• If setting hold ( HOLD ) to "L", the hold status starts when the serial clock goes in "L" after hold ( HOLD ) is switched.
• If setting hold ( HOLD ) to "H", the hold status ends when the serial clock goes in "L" after hold ( HOLD ) is switched.
Hold status
Hold status
SCK
HOLD
Figure 19 Hold Operation
Seiko Instruments Inc.
21