English
Language : 

S-82B1A Datasheet, PDF (17/35 Pages) Seiko Instruments Inc – BATTERY PROTECTION IC WITH CHARGE-DISCHARGE CONTROL FUNCTION FOR 1-CELL PACK
BATTERY PROTECTION IC WITH CHARGE-DISCHARGE CONTROL FUNCTION FOR 1-CELL PACK
Rev.1.2_00
S-82B1A Series
7. 0 V battery charge function "available"
This function is used to recharge a connected battery whose voltage is 0 V due to self-discharge. When the 0 V
battery charge starting charger voltage (V0CHA) or a higher voltage is applied between the EB+ and EB− pins by
connecting a charger, the charge control FET gate is fixed to the VDD pin voltage.
When the voltage between the gate and source of the charge control FET becomes equal to or higher than the
threshold voltage due to the charger voltage, the charge control FET is turned on to start charging. At this time, the
discharge control FET is off and the charging current flows through the internal parasitic diode in the discharging
control FET. When the battery voltage becomes equal to or higher than VDL, the S-82B1A Series enters the normal
status.
Caution
1. Some battery providers do not recommend charging for a completely self-discharged lithium-ion
rechargeable battery. Please ask the battery provider to determine whether to enable or inhibit
the 0 V battery charge function.
2. The 0 V battery charge function has higher priority than the charge overcurrent detection
function. Consequently, a product in which use of the 0 V battery charge function is enabled
charges a battery forcibly and the charge overcurrent cannot be detected when the battery
voltage is lower than VDL.
8. 0 V battery charge function "unavailable"
This function inhibits charging when a battery that is internally short-circuited (0 V battery) is connected. When the
battery voltage is the 0 V battery charge inhibition battery voltage (V0INH) or lower, the charge control FET gate is
fixed to the EB− pin voltage to inhibit charging. When the battery voltage is V0INH or higher, charging can be
performed.
Caution Some battery providers do not recommend charging for a completely self-discharged lithium-ion
rechargeable battery. Please ask the battery provider to determine whether to enable or inhibit the 0
V battery charge function.
9. Delay circuit
The detection delay times are determined by dividing a clock of approximately 4 kHz by the counter.
Remark
tDIOV1, tDIOV2 and tSHORT start when VDIOV1 is detected. When VDIOV2 or VSHORT is detected over tDIOV2 or tSHORT
after the detection of VDIOV1, the S-82B1A Series turns the discharge control FET off within tDIOV2 or tSHORT
of each detection.
VDD
DO pin voltage
VSS
VDD
VSHORT
VM pin voltage
VDIOV1
VSS
tSHORT
tD
0 ≤ tD ≤ tSHORT
Time
Figure 9
Time
17